Technical data

30 309030
Technical Data
Maximum working fluid pressure . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Maximum working air pressure . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Maximum compliant inbound air pressure (HVLP) . . . . 43 psi (300 kPa, 3 bar)
Maximum working fluid temperature . . . . . . . . . . . . . . . 120 F (49 C)
Minimum air cylinder actuation pressure . . . . . . . . . . . . 50 psi (0.34 MPa, 3.4 bar)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 lb (992 g)
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel, Ultra High Molecular Weight
Polyethylene, Chemically Resistant Fluoroelastomer,
Delrin, PTFE, PEEK
Teflon and Delrin are registered trademarks of the DuPont Company.
Triggering Speed
These values apply to a new gun with a 12 ft (3.6 m), 1/4 in. (6.3 mm) OD cylinder air line and a .055 in. nozzle.
These values will vary slightly with use and with variations in equipment.
Cylinder air pressure
psi (MPa, bar)
Fluid pressure
psi (MPa, bar)
Air pressure
psi (MPa, bar) msec to fully open msec to fully close
50 (0.35, 3.5) 50 (0.35, 3.5) 100 (0.7, 7.0) 58.4 50.4
Sound Data (dBa)
Air Cap
Part No.
Nozzle Part No.
and Size
Atomizing Air Pressure
psi (MPa, bar)
Fan Air Pressure
psi (MPa, bar)
Sound
Pressure
dB(A)†
Sound
Power
dB(A)‡
195304 192297, 0.055 in. 43 psi (300 kPa, 3.0 bar)
100 psi (0.7 MPa, 7.0 bar)
43 psi (300 kPa, 3.0 bar)
100 psi (0.7 MPa, 7.0 bar)
85.9
97
86.7
92.8
Sound pressure was measured at 1 meter from
unit.
Sound power was tested in accordance with ISO
9614–2.
Delrin® is a registered trademark of the DuPont Company.