Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES.
Replace seats and springs–Repair 
Kit RP4993. Check condition of lower O-rings and 
replace if necessary RP14414. See Helpful Hints 
1, 2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge RP46074. 
See Helpful Hints 1, 2, 3 & 5.
Unable to maintain constant water temperature:
Replace valve cartridge RP46074 or follow 
instructions in Helpful Hints 1, 2, 4 & 5. 
Helpful Hints:
1. Before removing valve cartridge assembly for any 
maintenance, be sure to note the position of the 
rotational limit stop on the cap. The valve cartridge 
assembly must always be put back in the same 
position. BE SAFE! After you have finished the 
installation, turn on valve to make sure COLD 
WATER FLOWS FIRST.  
2. To remove valve cartridge from body, shut off 
water supplies and remove handle and bonnet 
nut. Do not pry the valve cartridge out of the body 
with a screwdriver. Place handle on stem and rotate 
counterclockwise approximately 1/4 turn after the stop 
has been contacted. Lift valve cartridge out of body. 
3. To remove seats and springs, remove valve 
cartridge. Separate cap assembly from the 
housing assembly by rotating the cap assembly 
counterclockwise 90
o
 (degrees). Separate cap 
and housing assemblies. Remove seats and 
springs and replace. Place the largest diameter 
of the spring into the seat pocket first and then 
press the tapered end of the seal over the spring. 
Reassemble valve cartridge and replace in body 
following instructions given in 1 above. 
4. If the water in your area has lime, rust, sand or 
other contaminants in it, your pressure balance 
valve will require periodic inspection. The 
frequency of the inspection will depend on the 
amount of contaminants in the water. To inspect 
valve cartridge remove it and follow the steps 
in note 1 above. Turn the valve to the full mix 
position and shake the cartridge vigorously. If 
there is a rattling sound, the unit is functional and 
can be reinstalled following instructions given in 
note 1 above. If there is no rattle, replace valve 
cartridge RP46074. 
5. Push disc until fully seated. See pages 8 and 9 
for more details.
To order replacement parts, visit 
www.deltafaucet.com or call 
1-800-345-DELTA (3358) 
 13/14 Series Maintenance 
 Cleaning and Care 
Care should be given to the cleaning of this prod-
uct. Although its finish is extremely durable, it can 
be damaged by harsh abrasives or polish. To clean, 
simply wipe gently with a damp cloth and blot dry 
with a soft towel.
Warning: Scrubbing Bubbles
®
 Bathroom Cleaner 
and Lysol
®
 Basin Tub and Tile Cleaner must not be 
used on the clear knob handles and levers. Use of 
these cleaners can result in cracked or severely 
damaged handles. If overspray gets onto the 
handles, immediately wipe them dry with a soft 
cotton cloth