User's Manual
Turbo PMAC2 PCI Hardware Reference Manual
Baseboard Jumper Descriptions 17
E111-118: Command Output Disable State
E Point and
Physical Layout
Location Description Default
C1 Jump pin 1 to 2 of E11n for digital servo command
output signals of Channel n to tri-state when amplifier
enable signal for Channel n is in disable state.
Remove jumper for digital servo command output
signals of Channel n to remain active (but typically with
zero command value) when amplifier enable signal for
Channel n is in disable state.
No jumper installed