User's Manual

Turbo PMAC PCI HRM
Mating Connectors 39
MATING CONNECTORS
This section lists several options for each connector. Choose an appropriate one for an application.
(See the PMAC mating connector sketch for typical connection.)
Base Board Connectors
J1 (JDISP)/Display
Two 14-pin female flat cable connector Delta Tau P/N 014-R00F14-0K0, T&B Ansley P/N 609-1441
171-14 T&B Ansley standard flat cable stranded 14-wire
Phoenix varioface modules type FLKM14 (male pins) P/N 22 81 02 1
J2 (JPAN)/Control Panel
Two 26-pin female flat cable connector Delta Tau P/N 014-R00F26-0K0, T&B Ansley P/N 609-2641
171.26.T&B Ansley standard flat cable stranded 26-wire
Phoenix varioface module type FLKM 26 (male pins) P/N 22 81 05 0
J3 (JTHW)/Multiplexer Port
Two 26-pin female flat cable connector Delta Tau P/N 014-R00F26-0K0, T&B Ansley P/N 609-2641
171-26 T&B Ansley standard flat cable stranded 26-wire
Phoenix varioface module type FLKM 26 (male pins) P/N 22 81 05 0
J4 (JRS422)/RS232 or 422/Serial Communications
Two 26-pin female flat cable connector Delta Tau P/N 014-R00F26-0K0, T&B Ansley P/N 609-2641
171-26 T&B Ansley standard flat cable stranded 26-wire
Phoenix varioface module type FLKM 26 (male pins) P/N 22 81 05 0
J5 (JOPT)/OPTO I/O
Two 34-pin female flat cable connector Delta Tau P/N 014-R00F34-0k0, T&B Ansley P/N 609-3441
171-34 T&B Ansley standard flat cable stranded 34-wire
Phoenix varioface module type FLKM 34 (male pins) P/N 22 81 06 3
J6 (JXIO)/Expansion Board
Two 10-pin female flat cable connector Delta Tau P/N 014-R00F10-0K0, T&B Ansley P/N 609-1041
171-10 T&B Ansley standard flat cable stranded 10-wire
Phoenix varioface module type FLKM 10 (male pins) P/N 22 81 01 8
J7 (JMACH2)/Second Machine Connector (Option 1 Required)
Two 60-pin female flat cable connector Delta Tau P/N 014-R00F60-0K0, T&B Ansley P/N 609-
6041 available as Acc-8P or 8D
171-60 T&B Ansley tandard flat cable stranded 60-wire
Phoenix varioface module type FLKM 60 (male pins) P/N 22 81 09 2
Note:
Normally, J7 and J8 are used with Acc-8P or 8D with Option P, which provides
complete terminal strip fan-out of all connections.
J8 (JMACH1)/First Machine Connector
Two 60-pin female flat cable connector Delta Tau P/N 014-R00F60-0K0, T&B Ansley P/N 609-
6041 available as Acc-8P or 8D
171-60 T&B Ansley standard flat cable stranded 60-wire
Phoenix varioface module type FLKM 60 (male pins) P/N 22 81 09 2
Note: