Mating Connectors 39
MATING CONNECTORS
This section lists several options for each connector. Choose an appropriate one for an application.
(See the PMAC mating connector sketch for typical connection.)
Base Board Connectors
J1 (JDISP)/Display
• Two 14-pin female flat cable connector Delta Tau P/N 014-R00F14-0K0, T&B Ansley P/N 609-1441
• 171-14 T&B Ansley standard flat cable stranded 14-wire
• Phoenix varioface modules type FLKM14 (male pins) P/N 22 81 02 1
J2 (JPAN)/Control Panel
• Two 26-pin female flat cable connector Delta Tau P/N 014-R00F26-0K0, T&B Ansley P/N 609-2641
• 171.26.T&B Ansley standard flat cable stranded 26-wire
• Phoenix varioface module type FLKM 26 (male pins) P/N 22 81 05 0
J3 (JTHW)/Multiplexer Port
• Two 26-pin female flat cable connector Delta Tau P/N 014-R00F26-0K0, T&B Ansley P/N 609-2641
• 171-26 T&B Ansley standard flat cable stranded 26-wire
• Phoenix varioface module type FLKM 26 (male pins) P/N 22 81 05 0
J4 (JRS422)/RS232 or 422/Serial Communications
• Two 26-pin female flat cable connector Delta Tau P/N 014-R00F26-0K0, T&B Ansley P/N 609-2641
• 171-26 T&B Ansley standard flat cable stranded 26-wire
• Phoenix varioface module type FLKM 26 (male pins) P/N 22 81 05 0
J5 (JOPT)/OPTO I/O
• Two 34-pin female flat cable connector Delta Tau P/N 014-R00F34-0k0, T&B Ansley P/N 609-3441
• 171-34 T&B Ansley standard flat cable stranded 34-wire
• Phoenix varioface module type FLKM 34 (male pins) P/N 22 81 06 3
J6 (JXIO)/Expansion Board
• Two 10-pin female flat cable connector Delta Tau P/N 014-R00F10-0K0, T&B Ansley P/N 609-1041
• 171-10 T&B Ansley standard flat cable stranded 10-wire
• Phoenix varioface module type FLKM 10 (male pins) P/N 22 81 01 8
J7 (JMACH2)/Second Machine Connector (Option 1 Required)
• Two 60-pin female flat cable connector Delta Tau P/N 014-R00F60-0K0, T&B Ansley P/N 609-
6041 available as Acc-8P or 8D
• 171-60 T&B Ansley tandard flat cable stranded 60-wire
• Phoenix varioface module type FLKM 60 (male pins) P/N 22 81 09 2
Note:
Normally, J7 and J8 are used with Acc-8P or 8D with Option P, which provides
complete terminal strip fan-out of all connections.
J8 (JMACH1)/First Machine Connector
• Two 60-pin female flat cable connector Delta Tau P/N 014-R00F60-0K0, T&B Ansley P/N 609-
6041 available as Acc-8P or 8D
• 171-60 T&B Ansley standard flat cable stranded 60-wire
• Phoenix varioface module type FLKM 60 (male pins) P/N 22 81 09 2
Note: