Reference Manual
PMAC 2 Software Reference 
PMAC Firmware Updates  499 
25. Added five-line diagnostic method entry for highly interpolated sinusoidal encoders ($F) enabled by 
setting bit 19 of first setup line to 1, to calculate sum-of-squares magnitude or sine/cosine bias word 
(Geo PMAC only). 
26. Added amplifier status/fault code for seven-segment display (Geo PMAC only), including 
CLEARFAULT command to reset display. 
27. Added support for hardware position capture with highly interpolated sinusoidal encoders and capture of 
estimated sub-count position data in triggered moves with bits 18 and 19 of Ix03. 
28. Removed obsolete LIST LDS, <CTRL-E> and <CTRL-W> on-line commands and I47 variable. 
29. Corrected action of true deadband (Ix64=-16) with pulse-and-direction output to eliminate potential for 
dithering. 