User's Manual

Geo MACRO Drive User Manual
42 Connections
Connecting optional Analog Inputs (X6 & X7)
The MACRO Geo Drive can be ordered with two analog to digital converters (option 3/4/5). These A/D
converters are 16-bit devices that are ready to be used without any software setup. Delta Tau uses the
Burr Brown ADS8343 for this circuit.
The analog signals for analog input #1 are wired in to pins 5 (ADC1+) and 9 (ADC1-) of X6, and for
analog input #2 into pins 5 (ADC2+) and 9 (ADC2-) of X7.
Bipolar Analog Input
Function Pin #
GND 4
ANALOG+ 5
ANALOG- 9
2
3
4
5
6
7
8
9
1
X6/X7
-5VDC to
5VDC
Source
ANALOG+
ANALOG-.
Unipolar Analog Input
Function Pin #
GND 4
ANALOG+ 5
ANALOG- 9
2
3
4
5
6
7
8
9
1
X6/X7
-10VDC to
10VDC
Source
ANALOG+
ANALOG-.
GND