Geo MACRO Drive User and Reference Manual
Setting Up Turbo Motor Operation 95
Ixx91=$CB0000
Hex ($)
Bit
Value
C B
23 22 21 20
1 1 0 0
19
1
18
0
17 16
1 1
Reserved
0 0 0
14 13 1215
0 0 00
10 9 811
0 0 00
6 5 47
0 0 0 0
2 1 03
0 0 0 0
0
Hall Effect Offset ($0B)
Reversed Hall Sense (1)
Hall Effect Type Phase (1)