Installation manual
Geo Direct PWM Amplifier
Troubleshooting 51
Display
Code
Error / Fault
Description
Troubleshooting
Notes
GLOBAL
Normal Mode
Operation
No faults reported
Over
Voltage
The bus voltage has exceeded the permissible threshold:
420 VAC for GPL Drives
820 VAC for GPH Drives
Make sure that the external shunt is connected properly.
Make sure that the AC input is not excessively over spec.
Under
Voltage
No bus voltage input.
Bus voltage has dropped below the permissible threshold (97 VAC).
Shunt
Regulator
Shunt resistor leads or pins shorted.
Internal shunt regulator resistor failure.
Ground
Short
Motor leads shorted.
Shunt resistor leads or pins shorted.
Gate
Driver
Motor leads shorted
Shunt leads or pins shorted
Gate driver (internal) failure.
Line
Monitor
AC line voltage is low or not present.