Installation manual
Geo Direct PWM Amplifier
Drive Command Structure 47
Enhanced Mode
Enhanced mode enables access to and control of additional functions:
Bus voltage reading
IGBT temperature(s) reading
Set PWM control for brush motor
Turn Line Monitor off
Caution
The drive must be put in enhanced mode before accessing the
additional functions.
Caution
Once the drive is set up for enhanced mode, do not set it back to
default mode until the next logic power cycle.
PMAC Type
ADC Strobe Word
Enhanced
mode
Additional Functions
IGBT Temp
Bus Voltage
PWM For
Brush
Line
Monitor Off
Non-Turbo
WX:$C014
$C00003
$800003
$880003
$A00013
$A00023
Turbo
I7m06
Power PMAC2
Gate1[i].AdcStrobe
Power PMAC3
Gate3[i].AdcAmpCtrl
$C0000204
$80000204
$88000204
$A0001204
$A0002204
With Power PMAC3, setting the drive to enhanced mode requires the following motor setting changes:
Motor[x].PhaseCtrl = 4
Gate3[i].Chan[j].PackInData = 0
Gate3[i].Chan[j].PackOutData = 0
Note
Once in enhanced mode, the drive’s communication will remain in
enhanced mode until the next logic power cycle.