DRIVE COMMAND STRUCTURE
Default Mode
In default mode, the Geo Direct PWM Drive returns phases A and B current measurements as well as
global and axis faults.
Caution
The global and axes faults are in the lower 12 bits of ADC A, whereas the current measurements are in
the upper 12bits of ADC A:
ADC A Data Register
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Phase A Current Measurement
Global and Axis Faults
The ADC Strobe word must be set up properly for the data to come back correctly (and proper operation):
PMAC Type
ADC Strobe Word
Value
ADC A data register
Non-Turbo
WX:$C014
$3FFFFF
Y:$C005
Turbo
I7m06
$3FFFFF
Mxx05
Power PMAC2
Gate1[i].AdcStrobe
$3FFFFF
Gate1[i].Chan[j].Adc[0]
Power PMAC3
Gate3[i].AdcAmpCtrl
$FFFFFC02
Gate3[i].Chan[j].AdcAmp[0]