Installation manual
Geo Direct PWM Amplifier
Connector PinOuts and Wiring 32
X3: Discrete I/O for Motor Thermals
This 6-pin Phoenix Contact terminal block provides connectivity to low impedance 12 – 24 VDC motor
thermostat overload detection. This is a normally closed contact, in normal mode operation the Geo direct
PWM Drive expects to see 12 – 24 VDC coming into Pins #1 and #3 respectively for motors 1 and 2.
X3: Phoenix 6-Pin TB Female
Mating: Phoenix 6-pin TB Male
6
5
1
2
3
4
Pin #
Symbol
Function
Description
1
MTR1 PTC
Input
Motor 1 thermal
2
MTR 1 PTC RTN
Return
3
MTR2 PTC
Input
Motor 2 thermal
4
MTR2 PTC RTN
Return
5
24V RET
Common
6
N.C.
Not Connected
Part Type: FKMC 0,5/6-ST-2,5
Phoenix Contact p/n: 1881367
Note
If nothing is wired fault codes 5 and A are triggered respectively for
motors 1 and 2. Tie MTR PTC and MTR PTC RET to disable this
function.
Note
These contacts can be used for other general purpose safety functions
to kill motor power when desired.