Technical data

t +44(0) 121 327 7771 e sales@mwatechnology.com w www.mwatechnology.com t +44(0) 121 327 7771 e sales@mwatechnology.com w www.mwatechnology.com
10 11
MWA Code Size Model Height Width Depth CRS Qmin cmh Qmax cmh
KG2 ½" BSP G1.6 197 126 110 100 0.016 2.5
KG2P ½" BSP G1.6P 197 126 110 100 0.016 2.5
KG3 ¾" BSP G1.6 197 126 110 130 0.016 2.5
KG3P ¾" BSP G1.6P 197 126 110 130 0.016 2.5
KG4 ¾" BSP G2.5 214 164 130 130 0.025 4
KG4P ¾" BSP G2.5P 214 164 130 130 0.025 4
KG6 ¾" BSP G2.5 214 164 130 130 0.025 6
KG6P ¾" BSP G2.5P 214 164 130 130 0.025 6
WIZIT DIAPHRAGM GAS METERS
l Compact strong aluminium die cast construction
l High sensitivity suitable for low gas ow rates
l Suitable for Natural Gas, LPG, Air, Nitrogen and all inert gases
l Pulse lead supplied & tted
MWA
Code
Bosses
Distance Connections Type
Min
m
3
/hr
Nominal
m
3
/hr
Max
m
3
/hr
G4P 110mm 1" bsp unions supplied Pulse output, 1 pulse = 0.01 m
3
/hr 0.04 4 6.0
G6P 250mm 1" bsp unions supplied Pulse output, 1 pulse = 0.01 m
3
/hr 0.06 6 10.0
G10P 280mm 1.5" bsp unions supplied Pulse output, 1 pulse = 0.01 m
3
/hr 0.1 10 16.0
G16P 280mm 1.5" bsp unions supplied Pulse output, 1 pulse = 0.1 m
3
/hr 0.16 16 25.0
G25P 335mm 2" bsp unions supplied Pulse output, 1 pulse = 0.1 m
3
/hr 0.25 25 40.0
G40P n/a 65/100 mm anged PN6 Pulse output, 1 pulse = 0.1 m
3
/hr 0.4 40 65.0
G65P n/a 65/100 mm anged PN6 Pulse output, 1 pulse = 0.1 m
3
/hr 0.65 65 100.0
G1.6PBS 110mm 1" BS746 Pulse output, 1 pulse = 0.01 m
3
/hr 0.016 1.6 2.5
G2.5PBS 110mm 1" BS746 Pulse output, 1 pulse = 0.01 m
3
/hr 0.025 2.5 4.0
G4PBS 110mm 1" BS746 Pulse output, 1 pulse = 0.01 m
3
/hr 0.04 4 6.0
G6PBS 250mm 1" BS746 Pulse output, 1 pulse = 0.01 m
3
/hr 0.06 6 10.0
G10PBS 280mm 1.1/4" BS746 Pulse output, 1 pulse = 0.01 m
3
/hr 0.1 10 16.0
G16PBS 280mm 2" BS746 Pulse output, 1 pulse = 0.1 m
3
/hr 0.16 16 25.0
G25PBS 335mm 2" BS746 Pulse output, 1 pulse = 0.1 m
3
/hr 0.25 25 40.0
*P denotes pulse enabled
EUROPEAN DIAPHRAGM GAS METER
l Manufactured by BS EN ISO 9001 and ISO 14001
l G1.6 to G6 Fireproof up to 650 °C @ 100mbar according to EN1359
l Diaphragm gas meters, for natural gas, propane and butane, max pressure 500 mbar
l P = meters tted with pulse plug transmitter and 2 metre lead
l Meters read in cubic metres
l Optional M Bus output
GAS METERS
MWA Code Size Connections Pulse Values
Max
Pressure
Min
m
3
/hr
Max
m
3
/hr Weight
CGR40G16 1.5" PN16 anges Pulse output, 1 pulse = 0.01 m
3
/hr 20 bar 0.5 m
3
/hr 25.0 10kg
CGR40G26 1.5" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 0.8 m
3
/hr 40.0 10kg
CGR40G40 1.5" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 1.3 m
3
/hr 65.0 12kg
CGR50G16 2.5" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 0.5 m
3
/hr 25.0 10kg
CGR50G25 2" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 0.8 m
3
/hr 40.0 10kg
CGR50G40 2" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 1.3 m
3
/hr 65.0 12kg
CGR50G65 2" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 2.0 m
3
/hr 100.0 14kg
CGR80G100 3" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 3.0 m
3
/hr 160.0 19kg
CGR80G160 3" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 5.0 m
3
/hr 250.0 25kg
CGR100G100 4" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 3.0 m
3
/hr 160.0 19kg
CGR100G160 4" PN16 anges Pulse output, 1 pulse = 0.1 m
3
/hr 20 bar 5.0 m
3
/hr 250.0 25kg
CGR100G250 4" PN16 anges Pulse output, 1 pulse = 1 m
3
/hr 20 bar 8.0 m
3
/hr 400.0 31kg
CGR100G400 4" PN16 anges Pulse output, 1 pulse = 1 m
3
/hr 20 bar 13 m
3
/hr 650.0 42kg
MWA Code Size Connections
Max
Pressure
Min
m
3
/hr
Max
m
3
/hr Weight
QD 25 40mm Screwed 16 bar 0.8 m
3
/hr 25.0 3.6kg
QD 60 40mm Screwed 16 bar 2.0 m
3
/hr 60.0 3.6kg
CGR ROTARY GAS METER RANGE
lInline gas meter with wafer connections to suit PN16 anges,
ANSI 150 alternative
l Fitted with low frequency pulse output as standard
lAluminium body, suitable for natural gas and LPG, - 20 °C to +60 °C
lNominal rangeability 1:50, Meters read in cubic metres, index
can be head rotated through 360°
CGR ROTARY GAS METER ANCILLARIES
CGR calibration certicates
CGR 6 pin pulse plug
CGR 6 pin pulse plug and 2 metre lead
CGR high frequency pulse output - external
CGR high frequency pulse output - internal
CGR Remote 6 digit single LCD display Programmable installed in IP67 enclosure
CGR Chatterbox - e.Model unit, battery operated, 4 outputs, Atex IS.
CGR Chatterbox - e.Model unit, battery operated, 4 outputs, Atex IS. C/W enclosure
lDelta QD volumetric meters
l High accuracy and rangeability meter
lVery low pressure loss
lProtection class IP67
lATEX Directive 94/9/EC
(Intrinsic safety level: II ½G Ex ia IIC T5 c T6)
ROTARY METER DELTA QD
l Standard pulse output