User Manual
Delta-Q Technologies Corp.
3755 Willingdon Ave
Burnaby, BC V5G 3H3
Canada
tel: 604.327.8244
fax: 604.327.8246
email: info@delta-q.com
www.delta-q.com
For more information contact:
Electric Vehicle Battery Charger
• Advanced high frequency design with > 90% efficiency and >.99 power factor
• Wide range AC input (85 - 265 VAC) for worldwide operation
• Fully sealed enclosure provides improved reliability in demanding environments
• Approved battery charge algorithms for ideal charging
• Integrated Charge Tracking for Advanced Troubleshooting and Charge History Analysis
subject to change without notice
720-0001 Rev 5 October 7, 2011
QuiQ HF/PFC Battery Charger Specifications
QuiQ and the Power in Motion slogan are
trademarks of Delta-Q Technologies Corp.
Copyright © 2006 Delta-Q Technologies Corp.
QuiQ Model: 912- or 913-
24xx 36xx 48xx 72xx 84xx 96xx
DC Output
DC Output Voltage - nominal 24 V 36 V 48 V 72 V 84 V 96 V
DC Output Voltage - maximum 34 V 51 V 68 V 100 V 120 V 135 V
DC Output Current - maximum 25 A 21 A 18 A 12 A 10 A 9 A
DC Output Power - maximum 695 W 875 W 1000 W 1000 W 1000 W 1000 W
Interlock Current - maximum 1 A 1 A 1 A 0.5 A 0.5 A 0.5 A
Battery Type Specific to selected algorithm
Reverse Polarity Electronic protection – auto-reset
Short Circuit Electronic current limit
AC Input
AC Input Voltage - range 85 - 265 VAC
AC Input Voltage - nominal 120 VAC / 230 VAC rms
AC Input Frequency 45 - 65 Hz
AC Input Current - maximum/nominal 12 A / 9.5 A rms @ 120 VAC or 5 A rms @ 230 VAC
AC Power Factor - nominal > 0.99 @ 120 VAC / > 0.98 @ 230 VAC
Mechanical
Dimensions 28.0 x 24.6 x 11.0 cm (11 x 9.7 x 4.3”)
Weight < 5 kg (< 11 lbs) w/standard output cord
AC input connector IEC320/C14 (require ≥ 1.8m localized cord)
DC output connector OEM specific w/12AWG wire
Environmental
Enclosure IP66 (NEMA4)
Operating Temperature -30°C to +50°C (-22°F to 122°F), derated
above 30°C (86°F), below 0°C (32°F)
Storage Temperature -40°C to +70°C (-40°F to 158°F)
Regulatory
Safety UL approved to UL1564 3rd Ed., and CSA 107.2,
EN 60335-2-29, Designed to meet UL2202 1st Ed.
Emissions FCC Part 15/ICES 003 Class A, EN 55011,
EN 61000-3-2, EN 61000-3-3
Immunity EN 61000-4-2/-3/-4/-5/-6/-11
Operation
AC ON Solid YELLOW AC LED
>80% Charge Indicator Solid YELLOW Charge LED
100% Charge Indicator Solid GREEN Finish LED
Fault Indicator Flash RED Fault LED
DC Ammeter LED Bargraph (6 level)
Long-term Storage Mode Auto-restart if battery voltage < 2.1 V/cell or 30 days elapse
Special Features
Battery Temperature Monitoring with Multiple Temperature Sensor Options
External Communications
PC-based configuration software for field programmability
Advanced Microprocessor with Integrated Charge Cycle and Event Tracking
Options
• OEM Specific DC Output Cord
• Localized AC Input Cord
• Reverse or Dry Contact Interlocks
• Handle
Rear view of QuiQ ICON configuration shows inline DC and signal
connectors (charger output on left, signal I/O on right).
Mate with OEM specific output cords.
HF/PFC Battery Chargers
246 mm
9.7"
260 mm
10.2"
125 mm
4.9"
278 mm
10.9"