Instructions

HD32.2 - 17 - V1.4
5.2.2 Self Shut-off mode – The automatic switching off
Self shut-off mode heading controls the instrument automatic switching off mode during the
logging between the acquisition of a sample and the following one. With an interval less than 60
seconds, the instrument will always remain on. With intervals upper or equal to 60 seconds, it's
possible to choose switching the instrument off between the memorizations: it will switch on in
correspondence of the sampling time and it will switch off after some seconds, so extending the life
of the batteries.
Once you entered into LOGGING sub menu (previous paragraph), select Self shut_off mode
heading using arrow keys:
If the set Log Interval (see the previous paragraph) is less than 60 seconds, there will be
visualized:
WBGT Index
2008/11/10 08:00:00
Log interval<60 sec
During log session
the instrument
will STAY ON
between samples
If the set Log Interval (see the previous paragraph) is upper or equal to 60 seconds, there will
be visualixed:
WBGT Index
2008/11/10 08:00:00
Log interval>=60 sec
During log session
the instrument
will SHUT OFF
between samples
1. Pressing arrows, you can select:
STAY ON (the inswtrument remains on)
SHUT OFF (the instrument remains off)
Memorization
interval
Memory capacity
Memorization
interval
Memory capacity
15 secon
d
s About 11 days an
d
17 hours 10 minutes About 1 year an
d
104 days
30 secon
d
s About 23 days and 11 hours 15 minutes About 1 year and 339 days
1 minute About 46 days and 22 hours 20 minutes About 2 years and 208 days
2 minutes About 93 days and 21 hours 30 minutes About 3 years and 313 days
5 minutes About 234 days and 17 hours 1 hour About 7 years and 261 days