Data Sheet

2
[
GB
]
[ GB ]
HD208
Minidatalogger
Temperature – Temperature/Relative humidity
% Temperature or temperature/relative humidity and dew point data logger
% Available models with fixed probe or probe with cable
% Manual, also with configurable delay time, or programmed (date and time) logging
start
% Measurement alarms with configurable thresholds
% USB output
% Automatically generates PDF reports and CSV files
% Software for configuration, monitor and data download supplied
% Software option available for compliance with FDA 21 CFR part 11 recommendations
% LCD display and LED indicators for power, logging and alarms.
% Long life lithium battery
% Excellent weather protection
APPLICATIONS
%Monitoring of goods (food, drugs, plants, perishable products in general) during
transport and storage
%Laboratories
%Museums and document archives
DESCRIPTION
The data loggers of the series HD208 are compact instruments for monitoring
temperature, relative humidity (RH) and dew point temperature. Usable in a wide
spectrum of applications, are available in various models:
%With 1 channel for temperature only (depending on the model, the sensor can be
internal, external fixed or external with cable).
%With 1 channel for temperature and relative humidity (combined probe fixed or
with cable).
%With 2 channels for temperature only (one external sensor with cable and one
internal sensor).
%With 2 channels: one for temperature and relative humidity (combined probe with
cable) and one for temperature only (internal sensor).
All models can be supplied with or without LCD display.
The logging function is extremely versatile; logging can be started and stopped
manually, by means of the front buttons, or the start and stop date and time of
acqusition can be programmed. The delayed start capability allows starting the
logging with a configurable delay time after pressing the button for the manual start.
For each quantity detected, two configurable alarm thresholds can alert the user if the
measure exceeds the configured parameters.
The instrument automatically generates, after logging, a PDF report with charts
of the variables collected and a CSV file with all measurements logged. The PDF
and CSV files can then be copied to the PC via the USB port, without any dedicated
software: the instrument is recognized as a USB flash drive.
The basic application software HD35AP-S supplied with the instrument allows the
configuration of the instrument, the real-time monitor of the measurements and
the transfer of the acquired data into a database. The connection to the PC does
not require any installation of USB drivers, thereby ensuring compatibility with all
versions of the Windows® operating system.
The HD35AP-CFR21 application software option allows the use of security features
of the recorded data and configuration of the instrument in response to FDA 21 CFR
part 11 recommendations.
Powered by a 3.6 V non rechargeable lithium-thionyl chloride battery (Li-SOCl
2
).
The sensors are pre-calibrated and require no further calibration by the user. If
necessary, the user can perform a new calibration using the HD35AP-S application
software.
All versions can be ACCREDIA certified, upon quote.