Installation manual
EN
23Operation and installation manual SOLIVIA Gateway M1 G2
2. Keep the reset button pressed > 20 seconds
» LED blinks very fast for one second to indicate the reset has been recognized.
» All Parameters are reset to their default (factory settings), i.e.:
ü All network settings
ü Baud rate 19200
ü Interval 15 min
ü Power management is at 100 % for all relay state combination except
60 % for relay 1, 30 % for relay 2, and 0% for relay 3
ü Unbalanced load = 4.6 kVA
ü Clear all unbalanced conguration
ü Clear all power factor (cos phi) conguration
» This reset might require the reconguration from your public grid supplier.
13 ProductSpecication
RS485 INTERFACE
Max. in/output
voltage
± 5 V
Output current ≤ 250 mA
Input current ≤ 42 mA
POWER SUPPLY (INPUT 5 V DC)
Max. input voltage +8 V
Min. input voltage +4 V
Max. input current
≤ 600 mA
(3 W @ 5V)
Nom. input current
approx. 185 mA
(1 W @ 5 V)
AMBIENT CONDITIONS
Operating
temperature range
0 °C to 40 °C
Storage
temperature range
-40 °C to 80 °C
Relative humidity 0 % to 90 %
1) EXT. CONTROL
2) Use only the power supply adapter supplied with and suited for the SOLIVIA gateway
ETHERNET INTERFACE (LAN)
Max. in/output
voltage
± 3 V
Output current ≤ 20 mA
Input current ≤ 20 mA
RIPPLE CONTROL RECEIVER
INTERFACE
1)
Input voltage
(ports 1 to 8)
≤ 3.5 V
Input current
(ports 1 to 8)
≤ 1 mA
Output voltage
(ports A+B)
≤ 3.5 V
Output current
(ports A+B)
≤ 20 mA
POWER SUPPLY UNIT
2)
PSU voltage
range
4 V to 8 V
Max. output power ≥ 3 W (LPS certified)
Max. output
current
≥ 600 mA (LPS certified)