Installation manual
37
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
8. Commissioning
EN
➔
Baudrate: 19200
ID: 1
-------------------
RS485
16. To change the value, press the button and then set
the value using the
buttons. Press the button to
apply the value.
NOTE: If multiple solar inverters are
to be connected via RS485, select a
different ID for each inverter. The ID
is also used when saving and loading
settings in order to identify the solar
inverter.
Available IDs:
1 - 254
Available baudrates:
2400 | 4800 | 9600 | 19200 | 38400
➔
continue
Baudrate: 19200
ID: 1
-------------------
-------------------
RS485
17. Press the buttons to select continue and then
press the
button.
→ The completion screen will be displayed.
to reselect
ESC:
to confirm
ENTER:
18. Press the button to complete commissioning.
or
Press the
button to change settings.
þ Commissioning is now nished.
NOTE
► The solar inverter offers some optional
functions available for all grids, see “10 Set-
tings”, p. 52.
► When done with commissioning, save
the settings (see “11.4 Saving Settings”,
p. 65) and swap data (see “11.6 Saving
Swap Data”, p. 67) to a USB drive in
order to be able to use them later.