Installation manual
TECHNICAL SPECIFICATION TP-10-06 (6 CHANNEL)
POWER Voltage 230V AC nominal. (207V - 253V), 50Hz.
SUPPLY (110V 60Hz AC nominal available to order)
Single phase neutral and earth - three 20 amp live feeds.
Three phase neutral and earth Star configuration - 20 amp/phase.
(Three phase Delta configuration available to order)
Connection - hard wired to din rail mounting screw terminals.
TOT AL
CURRENT 60 AMP.
DIMMING Hard fired leading edge triac triggering.
OUTPUTS Maximum load 10 amps per channel resistive, 9 amps inductive.
Minimum load 40 watts per channel (200 watts for fluorescent -
ballasts, when channel set to switch output).
Output connections hard wired :-
Live and Neutral outputs - din rail mounting screw terminals.
Earth outputs - brass earth common bar.
EMERGENCY Six switched live outputs on channels 1,2,3,4,5, and 6.
OUTPUTS These outputs will normally give full mains output and under fault
conditions which trip the channel circuit breaker give zero output.
The total current on these channels emergency + dimmed must not
exceed the maximum channel rating.
PROTECTION Individual 10 amp Type C channel feed circuit breakers.
Green channel feed live indicators.
PSU module phase fuses 500mA anti-surge (3).
CONTROL 0-6V or 0-10V analogue, hard wired to screwless terminals.
INPUTS Mirage Scenario data bus, hard wired to screwless terminals.
USITT DMX512 (1990), hard wired or via 5 pin XLR.
RS-232 interface via 9 pin
D connector.
Alarm input - will set all alarm enabled channels to full output.
Control options set by DIP switches.
DC OUTPUTS +5V at 50mA and +15V at 50mA hard wired to screwless terminals.
DIMENSIONS Packed Unpacked
` Height 600mm 534mm
Width 400mm 322mm
Depth 240mm 160mm
Weight 11.3kgs 9.5kgs
FIXING CENTRES Vertical = 452mm Horizontal = 302mm
WARNING - Allow 300mm
top and at least 40mm side clearance
Between the side flanges and any other object.
This unit must be mounted vertically.
ENVIRONMENT Operating temperature 0ºC to +40ºC.
Maximum case temperature +90žC.
14