System information
Chapter 6 Troubleshooting
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
6-2
1. Transmission Rate 9600
2. Data Length 7-bit
3. Parity Check Even
4. Stop Bit 1-bit
RS232
Please note that if you want to download or upload program, you should enter TP04G main
menu to select 1. download program or 2. upload program and to get the following waiting
display first. Then, you should select “Transfer”> “Tp data read out” or “Tp data write in” in
TPEdit.
Waiting for Communicating...
If you want to use the cable that is made by yourself not DELTA DVPACAB530 cable,
please be careful with pin address.
2. The message of communication time-out occurs when connecting TP04G to PLC.
To check if communication protocol setting in TP04G system main menu is the same as
PLC communication protocol.
First, select 4. TP04G Settings in TP04G main menu to enter the following display.
1. Download TP04G <-- PC
2. Upload TP04G --> PC
3. Copy TP04G <--> PC
. TP04G Settings
5.
4
EXIT & RUN
ENTER
1. Communication Protocol
2. Contrast
3. Back-lighted
4. Date and Time
5. Buzzer
6. Language Settings
7. Password Settings
8. Start-up Display