System information
Chapter 3 TPEdit Software Operation
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
3-27
Step 2. Click reference device and you will get the following window.
Step 3. In this dialog box, you could set device name to be T, C and D and device
number to be 0~F. If your device name is AC driver, it doesn’t need to check
device name. It will show symbol $ to mean AC driver absolute address. What
you need is to input absolute address in device number.
Step 4. You could set device name, value type, value length, position, integer number,
decimal number, frame setting, font, blink and fill 0 into upper bit.
Step 5. Value type could be unsigned decimal, signed decimal, hexadecimal, ASCII,
Binary or BCD code. Value length could be 16 bits or 32 bits. The position
could be right side, left side and middle.
Step 6. The digital numbers of integer and decimal according to the setting of display
value number. For example, if the real value of timer T0 is 50 seconds, if you
set integer number is 3 and decimal number is 0 and it will display 500. If you
set 3 for integer number and 1 for decimal number and it will display 050.0.
Step 7. The settings of frame could be no frame, double-line frame, bold frame and
the font size could be 5X8, 8X8, 8X12 and 8X16.
Step 8.You could choose to fill 0 in upper bit or not. For example, there are 6 integer
numbers and 2 decimal numbers of a value. If you check to fill 0, the value
324836 will display to 003248.36. If you don’t check to fill 0, the value 324836
will display to 3248.36.