Environmental Specifications
Parameter Conditions Min. Max. Unit
Operating Temperature Range (with Derating) Ambient -40 +85
Case Temperature --- +90
Storage Temperature Range -50 +125
Humidity (non condensing) --- 95 % rel. H
Cooling Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.) --- 260
Power Derating Curve
Notes
1 Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
3 Ripple & Noise measurement bandwidth is 0-20MHz.
4 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will
not damage these modules; however they may not meet all specifications listed.
5 All DC/DC converters should be externally fused at the front end for protection.
6 Specifications subject to change without notice.
Mechancial Drawing
Mechanical Dimensions Connecting Pin Patterns
All dimensions in mm (inches)
Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
Pins ±0.05 (±0.002)
P3
20.8 [0.82]
22.6 [0.89]
25.6 [1.01]
2.76
5.08
15.24 [0.6]
[0.2]
7.62
[0.3]
33.4 [1.31]
1.50 [0.06]
1
24
2
23
3
22
10
15
11
14
12
1316
9
10.2 0.5
[0.4 0.02]
0.4
9.8 [0.39]
[0.02]
0
~
5
0.15 S
SSEATING
PLANE
[0.11]
3.0 [0.12]
27.94 [1.10]
2.54 [0.10] 15.24 [0.60] 1.9 [0.07]
27.0 [1.06]