Datasheet
DS_SD02S/D_03152012           E-mail: DCDC@delta.com.tw 
http://www.delta.com.tw/dcdc 
Input Characteristics 
Parameter  Model  Min.  Typ.  Max.  Unit 
5V Input Models  -0.7 ---  11 
12V Input Models  -0.7 ---  25 
24V Input Models  -0.7  ---  50 
Input Surge Voltage (1 sec. max.) 
48V Input Models  -0.7  ---  100 
5V Input Models  3.5 4 4.5 
12V Input Models  4.5 7  9 
24V Input Models  8  12  18 
Start-Up Voltage 
48V Input Models  16 24 36 
5V Input Models  --- 3.5  4 
12V Input Models  --- 6.5 8.5 
24V Input Models  ---  11  17 
Under Voltage Shutdown 
48V Input Models  ---  22  34 
VDC 
Reverse Polarity Input Current  ---  ---  1  A 
Short Circuit Input Power  ---  ---  1500  mW 
Internal Power Dissipation  ---  ---  1800  mW 
Conducted EMI 
All Models 
Compliance to EN 55022,class A and FCC part 15,class A 
Output Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
Output Voltage Accuracy    ---  ±1.0  ±2.0  % 
Output Voltage Balance  Dual Output, Balanced Loads ---  ±1.0  ±2.0  % 
Line Regulation  Vin=Min. to Max.  ---  ±0.3  ±0.5  % 
Load Regulation  Io=25% to 100%  ---  ±0.5  ±0.75  % 
Ripple & Noise (20MHz)    ---  30  50  mV 
P-P
Ripple & Noise (20MHz)  Over Line, Load & Temp.  ---  ---  75  mV 
P-P
Ripple & Noise (20MHz)    ---  ---  15  mV rms 
Transient Recovery Time  ---  100  300  uS 
Transient Response Deviation 
25% Load Step Change 
--- ±3 ±5 % 
Temperature Coefficient    ---  ±0.01  ±0.02  %/℃ 
Short Circuit Protection    Continuous 
General Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
I/O Isolation Voltage (rated)  60 Seconds  1500  ---  ---  VDC 
I/O Isolation Resistance  500 VDC  1000  ---  ---  MΩ 
I/O Isolation Capacitance  100KHz, 1V  ---  250  420  pF 
Switching Frequency    ---  300  ---  KHz 
MTBF (calculated)  MIL-HDBK-217F@25℃, Ground Benign  1,000,000 ---  ---  Hours 
Moisture Sensitivity Level (MSL)  IPC/JEDEC J-STD-020D  Level 2 
Recommended Input Fuse 
5V Input Models  12V Input Models  24V Input Models  48V Input Models 
1000mA Slow-Blow Type  500mA Slow-Blow Type  250mA Slow-Blow Type  120mA Slow-Blow Type 
Environmental Specifications 
Parameter  Conditions  Min.  Max.  Unit 
Operating Temperature Range (with Derating)  Ambient  -40  +85  ℃ 
Case Temperature    ---  +90  ℃ 
Storage Temperature Range    -50  +125  ℃ 
Humidity (non condensing)    ---  95  % rel. H 
Cooling  Free-Air convection 
Lead Temperature (1.5mm from case for 10Sec.)    ---  260  ℃ 
P2 