Datasheet
DS_SC02S/D_03152012           E-mail: DCDC@delta.com.tw 
http://www.delta.com.tw/dcdc 
Output Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
Output Voltage Accuracy    ---  ±1.5  ±4.0  % 
Output Voltage Balance  Dual Output, Balanced Loads ---  ±0.1  ±1.0  % 
Line Regulation  For Vin Change of 1%  ---  ±1.2  ±1.5  % 
Load Regulation  Io=20% to 100%  See Model Selection Guide 
Ripple & Noise (20MHz)    ---  100  120  mV
 P-P
Ripple & Noise (20MHz)  Over Line, Load & Temp.  ---  ---  200  mV
 P-P
Ripple & Noise (20MHz)    ---  ---  15  mV rms 
Temperature Coefficient    ---  ±0.01  ±0.02  %/℃ 
Short Circuit Protection    0.5 Second Max. 
General Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
I/O Isolation Voltage (rated)  60 Seconds  1000  ---  ---  VDC 
I/O Isolation Resistance  500 VDC  1000  ---  ---  MΩ 
I/O Isolation Capacitance  100KHz, 1V  ---  60  100  pF 
Switching Frequency    50  100  120  KHz 
MTBF (calculated)  MIL-HDBK-217F@25℃, Ground Benign  2,000,000 ---  ---  Hours 
Moisture Sensitivity Level (MSL)  IPC/JEDEC J-STD-020D  Level 3 
Recommended Input Fuse 
5V Input Models  12V Input Models  24V Input Models 
1000mA Slow-Blow Type  500mA Slow-Blow Type  200mA Slow-Blow Type 
Environmental Specifications 
Parameter  Conditions  Min.  Max.  Unit 
Operating Temperature Range (with Derating)  Ambient  -40  +85  ℃ 
Case Temperature    ---  +90  ℃ 
Storage Temperature Range    -50  +125  ℃ 
Humidity (non condensing)    ---  95  % rel. H 
Cooling  Free-Air convection 
Lead Temperature (1.5mm from case for 10Sec.)    ---  300  ℃ 
Power Derating Curve 
Output Power (%)
Notes 
1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 
2  Ripple & Noise measurement bandwidth is 0-20MHz. 
3  These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will 
not damage these modules; however they may not meet all specifications listed. 
4  All DC/DC converters should be externally fused at the front end for protection. 
5  Specifications subject to change without notice. 
P2 