Datasheet

S24SE/S24DE series
20W Single/Dual Output DC/DC Converter
DS_S24SE/S24DE 20W _03262013
E-mail:DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P2
Output Characteristics
Item Conditions Min. Typ. Max. Unit
Output Voltage Accuracy
--- ±1.0 ±2.0 %Vo
Output Voltage Balance
Dual Output, Balanced Loads ---
±1.0 ±2.0 %Vo
Single output
±0.1 ±0.2 %Vo
Line Regulation
Dual output
±0.1 ±0.5 %Vo
Cross Regulation
Dual output,Asymmetrical Load
25%-100% Full Load
±2 ±3 %Vo
Total Outupt Voltage Range Over Load, Line and Temperature --- --- ±3 %Vo
Ripple & Noise 12V, 15V, ±12V, ±15V --- 50 --- mV
P-P
Ripple & Noise 3.3V, 5.0V 50 --- mV
P-P
Dynamic load response 50%-75% full load, 0.1A/uS 3 %Vo
Output Over Current Protection Output Voltage 10% Low, Hiccup 110 160 %Iomax
Short Output Protection Long Term, Auto-recovery
Output Over-Voltage Protection Hiccup, Auto-recovery 115 150 %Vo
Output Trim Range Single Output -10 +10 %Vo
General Characteristics
Item Conditions Min. Typ. Max. Unit
I/O Isolation Voltage (rated) --- --- 1600 VDC
I/O Isolation Resistance 10 --- --- M
I/O Isolation Capacitance 1100 pF
Switching Frequency 550 KHz
Environmental Specifications
Parameter Conditions Min. Max. Unit
Operating Temperature Range (with Derating) Ambient -40 +85
Case Temperature --- +105
Storage Temperature Range -50 +125
Humidity (non condensing) --- 95 % rel. H
Cooling Free-Air convection
Power Derating Curves (No Heat Sink and With Heat Sink)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
110%
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
Output Power(%)
Ambient Temperature (
)
Natural
Convection
S24SE&S24DE_20W Series (Encapsulation) Output Power vs. Ambient Temperature
at Natural Convection
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
110%
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
Output Power(%)
Ambient Temperature ()
Natural
Convection
S24SE &S24DE_20W Series (Encapsulation) Output Power vs. Ambient Temperature
at Natural Convection (with Heat Sink)
Notes
1 Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 Ripple & Noise measurement bandwidth is 0-20MHz, with 10µF, tantalum capacitor and 1µF ceramic capacitor.
3 All DC/DC converters should be externally fused at the front end for protection.