Datasheet

S24SE/S24DE series
10W Single/Dual Output DC/DC Converter
DS_ S24SE/S24DE 10W _ 06032014 E-mail:DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P1
Model List
Model
Number
Input
Voltage
(Range)
Output
Voltage
Output Current
Input Current
(typ input voltage)
Load
Regulation
Efficiency
(typ.)
Max.
Min.
@Max. Load
@No Load
@Max. Load
VDC
VDC
mA
mA
mA(typ.)
mA(typ.)
mV
%
S24SE3R303
24
(9 ~ 36)
3.3V
3000
0
490
35
±10
87%
S24SE05002
5.0V
2000
0
490
35
±10
87%
S24SE120R8
12V
830
0
500
30
±12
86%
S24SE150R6
15V
670
0
490
25
±15
87%
S24DE120R4
±12V
420
0
490
20
±120
87%
S24DE150R3
±15V
330
0
490
30
±150
87%
Input Characteristics
Item
Model
Min.
Typ.
Max.
Unit
Input Surge Voltage (100 msec)
All Models
50
VDC
Input Turn-On Voltage Threshold
All Models
8
8.5
9
VDC
Input Turn-Off Voltage Threshold
All Models
7
7.5
8
VDC
Input Under-Voltage Lockout Hysteresis
All Models
0.4
1
1.7
VDC
Off-Converter Input Current
All Models
6
mA
Input reflected ripple current
All Models,with 12uH, 20MHz
5
20
mA
Reverse Polarity Input Current
All Models
---
---
0.3
A
ON/OFF Control, Logic High
All Models
2.4
10
VDC
ON/OFF Control, Logic Low
All Models
-0.7
0.8
VDC
Input Filter
All Models
Internal PI Filter
FEATURES
Efficiency up to 87%
Wide input range, 9V-36V
Package with Industry Standard Pinout
Package Dimension:
25.4 x25.4 x10.2mm (1.0 x1.0 x0.40”)(No HSK)
31.0 x25.4 x17.5mm (1.22” x1.00” x0.69”)(HSK)
Over voltage protection, hiccup mode
Over current protection, hiccup mode
Positive or Negative Remote ON/OFF
Without tantalum capacitor inside module
Operating Temperature range - 40°C to +85°C
Input to Output Isolation: 1600VDC
RoHs Compliant
3 Years Product Warranty
Heat-sink is option
UL60950, 2
nd
Edition, 2011-12-19 Recognized
The S24SE/S24DE series is miniature, isolated 10W DC/DC converters with 1600VDC isolation. The S24SE/S24DE family comes with
a host of industry-standard features, such as over current protection, over voltage protection, over temperature protection and remote on/off.
An optional heatsink is available for more extreme thermal requirements. All models have an untra-wide 4:1 input voltage range (9V to 36V).
With operating temperature of -40°C to +85°C, it is suitable for customers’ critical applications, such as process control and automation,
transportation, data communication and telecom equipment, test equipment, medical device and everywhere where space on the PCB is
critical.

Summary of content (12 pages)