Datasheet

DS_PM05S_11212014 E-mail: dcdc@deltaww.com
http:// www.deltaww.com/dcdc
P2
Output Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
Output Voltage Setting Accuracy
---
±2.0
±3.0
%Vnom.
Line Regulation
Vin=Min. to Max.
1.5V to 6.5V
---
±0.2
±0.4
%
9V to 15V
---
±0.1
±0.2
%
Load Regulation
Io=10% to 100%
1.5V to 6.5V
---
±0.4
±0.6
%
9V to 15V
---
±0.25
±0.4
%
Min.Load
No minimum Load Requirement
Ripple & Noise (20MHz)
1.5V to 6.5V
---
20
30
mV
P-P
9V to 15V
---
30
40
mV
P-P
Transient Recovery Time
50% Load Step Change
---
100
---
μsec
Transient Response Deviation
---
±2
---
%
Temperature Coefficient
---
---
±0.015
%/
Output Current Limit
---
---
1
A
Short Circuit Protection
Continuous
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
none
Switching Frequency
280
330
380
KHz
MTBF(calculated)
MIL-HDBK-217F@25, Ground Benign
2,000,000
---
---
Hours
Environmental Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
Operating Ambient Temperature Range (See Power Derating
Curve)
Natural Convection
-40
---
+90
Case Temperature
---
---
+100
Storage Temperature
-55
---
+125
Thermal Shutdown
Internal IC junction
---
160
---
Humidity (non condensing)
---
---
95
% rel. H
Lead Temperature (1.5mm from case for 10Sec.)
---
---
260
EMC Characteristics
Parameter
Standards & Level
Performance
Conducted EMI
Compliance to EN55022 and FCC part 15
Class B (See Page 3)
Radiated Emissions
EN55022
Class B
ESD
EN61000-4-2
Class A
Radiated immunity
EN61000-4-3
Class A
Fast transient (See Note 5)
EN61000-4-4
Class A
Conducted immunity
EN61000-4-6
Class A
Magnetic Field Immunity
EN61000-4-8
Class A