Power Derating Curve
~
]Ambient Temperature
Output Power (%)
0
20
40
60
80
100
-40 0 20 60 100 110
8040
Natural
convection
100LFM
200LFM
400LFM
Notes
1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3 Ripple & Noise measurement bandwidth is 0-20 MHz.
4 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will
not damage these modules; however, they may not meet all specifications listed.
5 All DC/DC converters should be externally fused at the front end for protection.
6 Specifications subject to change without notice.
Mechancial Drawing
Mechanical Dimensions Pin Connections
Pin Single Output Dual Output
1 -Vin -Vin
2 +Vin +Vin
3
Remote Remote
6 +Vout +Vout
7 NC Common
8 NC NC
9 -Vout -Vout
NC: No Connection
►All dimensions in mm (inches)
►Tolerance: X.X±0.5 (X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
►Pins ±0.1(±0.004)
Physical Outline
Case Size :
25.95x9.25x12.45 mm (1.02x0.36x0.49 inches)
Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight : 6.5g
P3
2.00
[0.08]
2X2.54
[2X0.10]
7.62
[0.30]
3X2.54
[3X0.10]
25.95 [1.02]
0.5 [0.02]
12.45 [0.49]
3.2
[0.13]
0.5
[0.02]
0.50
[0.02]
24.95 [0.98]
0.25 [0.01]
Bottom View
3.0 [0.12]
9.25 [0.36]
123 6789