Parameter  Model  Min.  Typ.  Max.  Unit 
5V Input Models  4.5 5 5.5 
12V Input Models  10.8 12 13.2 Input Voltage Range 
24V Input Models  21.6 24 26.4 
5V Input Models  -0.7 ---  9 
12V Input Models  -0.7 ---  18 
Input Surge Voltage (1 sec. max.) 
24V Input Models  -0.7  ---  30 
VDC 
Reverse Polarity Input Current  ---  ---  0.3  A 
Input Filter  Internal Capacitor 
Internal Power Dissipation 
All Models 
--- --- 450 mW 
Output Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
Output Voltage Accuracy 
--- ±1.0 ±3.0 % 
Output Voltage Balance 
Dual Output, Balanced Loads ---  ±0.1  ±1.0 
% 
Line Regulation 
For Vin Change of 1%  ---  ±1.2  ±1.5 
% 
Load Regulation 
Io=20% to 100% 
See Model Selection Guide 
Ripple & Noise (20MHz)    ---  65  100  mV
 P-P
Ripple & Noise (20MHz)  Over Line, Load & Temp.  ---  ---  150  mV
 P-P
Ripple & Noise (20MHz)    ---  ---  15  mV rms 
Temperature Coefficient    ---  ±0.01  ±0.02  %/℃ 
Short Circuit Protection    0.5 Second Max. 
General Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
I/O Isolation Voltage (rated)  60 Seconds  3000  ---  ---  VDC 
I/O Isolation Resistance  500 VDC  10  ---  --- GΩ 
I/O Isolation Capacitance  100KHz, 1V  ---  60  100  pF 
Switching Frequency    70  100  120  KHz 
MTBF (calculated)  MIL-HDBK-217F@25℃, Ground Benign  2,000,000 -----  -----  Hours 
Recommended Outside Input Fuse 
5V Input Models  12V Input Models  24V Input Models 
500mA Slow-Blow Type  200mA Slow-Blow Type  100mA Slow-Blow Type 
Environmental Specifications 
Parameter  Conditions  Min.  Max.  Unit 
Operating Temperature Range (with Derating) 
Ambient -40  +85  ℃ 
Case Temperature 
 --- +90 ℃ 
Storage Temperature Range 
 -50 +125 ℃ 
Humidity (non condensing)   
---  95  % rel. H 
Cooling  Free-Air convection 
Lead Temperature (1.5mm from case for 10Sec.)    ---  260  ℃ 