Technical information
J-33
Above prices do not include VAT. E&OE
Monitoringdevices
Function Digital counter/timer
Digital temperature controller with timer
Digital temperature controller
Model DDCT DDCT/B DDTCT DDTC
Description of operation
Function 1: Counter
Canbesettocountupand/ordown.Apre-scaler
canbeselectedThepulselengthcanbeadjusted.
Thede-bouncetimecanbesettoeliminate
contactbounceonamechanicalswitch.The
countercanbemanuallyresetwiththeresetinput
(pin9)
Function 2: Timer
Thetimercanbesettocountupordown.The
pulselengthcanbesetinthemenu.Thetimercan
bemanuallyresetwiththeresetinput(pin9)
Function 3:Timerwithstart/Stop
ThetimercanbestartedandstoppedbyInput1
(pin13).ThetimerwillstarttimingwhenInput1is
activatedandstopwhenitisactivatedagain.
Function 4:timerwithtimingonactivation
WhenInput1isactivatedthetimerstartstiming
andwillstopifInput1isde-activated.
MenuDiagram
“SET”ButtonMomentarily
Count/Timesetpoint
“SET”Button4seconds
 /Bwithbackupforcounter/timer
Temperature Controller
Thetemperaturerelayremainsenergizeduntilthe
measuredtemperatureisabovethesetpoint.If
thetemperaturemovesbelowthesetpointminus
thehysteresistherelayenergisesandwillonly
de-energisewhenthetemperaturemovesabove
thesetpoint.Thehysteresiseliminateschattering
offthecontacts.
Timer
TheTimingcontactwillcloseiftheclocktime,set
intheadvancedfunctionfallsbetweenthetwoset
times.Thetimeclockhasbatterybackupandwill
keepthetimeevenafterpowerisremoved.
MenuDiagram
“SET”ButtonMomentarily
Temperature setpoint
“SET”Button4seconds
Clock
OnTime1
OffTime1
OnTime2
OffTime2
Over ride On Time
InterfaceswithTP1probe
Atrippointcanbesetforeachofthetworelays.
Hysteresisforeachtrippointscanbeset.The
tworelaycanbesetindependentlyforoveror
underoperation.Themaximumandminimum
temperatureforthesetpointadjustmentcan
also be set.
MenuDiagram
“SET”ButtonMomentarily
Temperature setpoint
“SET”Button4seconds
Functionsetting(forfutureuse)
Hysterisis1
Hysterisis2
Maxtemperaturesetpoint
Min temperature set point
Heating/Cooling1
Heating/Cooling2
InterfaceswithTP1probe
Galvanic insulation
110,230,400,525Vareequippedwithinternaltransformervoltage(testvolts:2k)
Range accuracy
±0.2%
Repeat accuracy
±0.2%
Time adjustment
NA
Standard voltages
AC:110,230,400,525V+/-15%
Contact rating
10A 6A 6A
Consumption
AC:±2.4VA
Reset time
0.5sec(500mSec)
Insulation
4kVbetweensupply/outputandadjacentcontacts
1kVbetweenopencontacts.
Mechanical life
30millionoperations
Ambient limits
(operating)-20+60°C
Connection diagram
Price 718.00 824.00 824.00 718.00
1-Counter 2-Timer 3-Timer 4-Timer
pulsestart/
stop
start/stop
Debounce Up/Down Up/Down Up/Down
Pre-scalar Pulselength Pulselength Pulselength
Up/down Range Range Range
Pulse 
length
Showrelay Showrelay Showrelay
Showrelay