Technical information
J-19
Above prices do not include VAT. E&OE
SN1
LVM25
LVM20
LVM30
LVMP...
LVM40
Levelcontrols/Relays
Level control relays
• Levelmonitoringforelectricallyconductiveliquids
• ModularDINrailmounting(aligns with standard MCB’s)
• Adjustablesensitivity
• Doubleinsulationbetweensupply,electrodesandoutputrelay
type description
supply module
price
voltage width
LVM20 threedetectingprobes(Min, Max and Com)
• Adjustments: -sensitivity 2.5-50kΩ
• Emptyingfunction
LVM20A240 liquidlevelcontrolrelay “emptying” 220-240Vac 35mm 550.00
LVM20A415 liquidlevelcontrolrelay “emptying” 380-415Vac 35mm 550.00
LVM25 threedetectingprobes(Min, Max and Com)
• Slimlineonemodule(17.5mm)wide
• Adjustments: -sensitivity: 2.5-50kΩ
• Selectable: “emptying”(or)“filling”function(with fail safe operation)
• Multi-voltage: 24-240Vac/dc
LVM25240 multi-voltageliquidlevelcontrolrelay 24-240V 18mm 778.00
LVM30 threedetectingprobes(Min, Max and Com)
• Adjustments: - sensitivity: 2.5-50kΩ
- probesignaldelay: 1-10sec
- pumpstartdelay: 0-30min
• Selectable: “emptying”(or)“filling”function(with fail safe operation)
• Dualvoltage: (A240)24Vac/220-240Vac-(A415)110-127/380-415Vac
LVM30A240 liquidlevelcontrolrelay 24/240Vac 54mm 916.00
LVM30A415 liquidlevelcontrolrelay 127/415V 54mm 916.00
LVM40 fivedetectingprobes(Min1, Max1, Min2, Max2 and Com)
• Adjustments: - sensitivity: 2.5-200kΩ(sep adj for Max for foam detection)
- probesignaldelay: 1-10s
- pumpstartdelay: 0-300s
• Selectable: 5xdifferentfunctions
- standardemptyingandalarms
- standardfillingandalarms
- emptyingandfillingwithprioritystart-upchangecontrol
- fillingandfillingwithprioritystart-upchangecontrol
- welldrainingandtankfillingandalarms
• Relayoutputs: 1xchangeover1xNO
LVM40A240 5probeliquidlevelcontrolrelay 220-240Vac 54mm 1373.00
LVM40A415 5probeliquidlevelcontrolrelay 380-415Vac 54mm 1373.00
Level electrodes and holders for conductive liquids
SN1 1-poleinsulatedelectrode(AISI 303 stainless steel)forLVMrelays 97.00
PS3S electrodeholderfor3rodprobes 98.00
P1000S electrodesforPS3Sholder (1 meter length) 46.00
FS03-3P electrode spacer disc (for extended probe length) 20.00
PXL extensionlocknut (for extending probe length) 14.00
Pump start-up priority change relay
Tobalanceoperationtimes,hencewearoftwopumps,compressors,generatorswhentwo
units (primary and standby) are installed in an installation.
• 2outputs2NO(SPST)
• Multi-voltagesupply:24/48Vdc/24-240Vac
LVMP05 pumpprioritychangerelay 24-48Vdc/24-240Vac 18mm 595.00
LVMP10A240 pumpprioritychangerelay2NOoutputs 220-240Vac 54mm 916.00