Datasheet
DS_DNM10SMD10_07182012
12
THERMAL CURVES
Figure 31: Temperature measurement location
The allowed maximum hot spot temperature is defined at 125
℃
DNM10S0A0S10(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 10V, Vo = 5.0V (Either Orientation)
0
2
4
6
8
10
12
60 65 70 75 80 85
Ambient Temperature (℃)
Output Current(A)
Natural
Convection
100LFM
200LFM
300LFM
400LFM
Figure 32: DNM10S0A0S10(Standard) Output current vs.
ambient temperature and air velocity@ Vin=10V, Vo=5.0V(Either
Orientation)
DNM10S0A0S10(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 10V, Vo = 1.8V (Either Orientation)
0
2
4
6
8
10
12
60 65 70 75 80 85
Ambient Temperature (℃)
Output Current(A)
Natural
Convection
100LFM
Figure 33: DNM10S0A0S10(Standard) Output current vs.
ambient temperature and air velocity@ Vin=10V,
Vo=1.8V(Either Orientation)
DNM10S0A0S10(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 10V, Vo = 0.75V (Either Orientation)
0
2
4
6
8
10
12
60 65 70 75 80 85
Ambient Temperature (℃)
Output Current(A)
Natural
Convection
Figure 34: DNM10S0A0S10(Standard) Output current vs.
ambient temperature and air velocity@ Vin=10V,