FEATURES DESCRIPTIONS 
Remote On/Off 
The DCL series power modules have an On/Off pin for remote 
On/Off  operation.  Both  positive  and  negative  On/Off  logic 
options are available in the DCL series power modules. 
For positive logic module, connect an open collector (NPN) 
transistor  or open  drain  (N channel) MOSFET  between  the 
On/Off pin and the GND pin (see figure 30). Positive logic On/Off 
signal turns the module ON during the logic high and turns the 
module OFF during the  logic  low.  When  the positive On/Off 
function is not used, leave the pin floating or tie to Vin (module 
will be On). 
For negative logic module, the On/Off pin is pulled high with an 
external pull-up 5kΩ resistor (see figure 31). Negative logic 
On/Off signal turns the module OFF during logic high and turns 
the module ON during logic low. If the negative On/Off function 
is not used, leave the pin floating or tie to GND. (module will be 
on) 
Vo
O n /O ff
V in
GND
Q1
RL
I
O N /OFF
Figure 30: Positive remote On/Off implementation   
Vo
On/Off
Vin
GND
Q1
RL
Rpull-
up
I
ON/O FF
Figure 31: Negative remote On/Off implementation   
Input Under voltage Lockout 
At input  voltages below the input under voltage lockout  limit, the 
module operation is disabled. The module will begin to operate at 
an input voltage above the under voltage lockout turn-on threshold. 
Over-Current Protection 
To provide protection in an output over load fault condition, the unit 
is  equipped  with  internal  over-current  protection.  When  the 
over-current  protection  is triggered, the  unit enters  hiccup mode. 
The units operate normally once the fault condition is removed. 
Remote Sense 
The DCL provide Vo remote sensing to achieve proper regulation 
at the load points  and  reduce effects of distribution losses on 
output line. In the event of an open remote sense line, the module 
shall maintain local sense regulation through an internal resistor. 
The  module shall  correct  for a  total  of 0.5V  of  loss.  The remote 
sense line impedance shall be < 10. 
Vo
Sense
Vin
GND
RL
Distribution Losses
Distribution Losses
Distribution 
Losses
Distribution 
Losses
Figure 32: Effective circuit configuration for remote sense 
operation 