User manual
Chapter 5 Trial Run and Tuning Procedure ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-6
Overcurrent:
Corrective Actions:
Check the wiring connections between drive and motor.
Check if the circuit of wire is closed.
Repair the short-circuited and avoid metal conductor being exposed.
7) When display shows:
Undervoltage:
Corrective Actions:
Check whether the wiring of main circuit input voltage is normal.
Use voltmeter to check whether input voltage of main circuit is normal.
Use voltmeter to check whether the input voltage is within the specified specification.
Note: If there are any unknown fault codes and abnormal display when applying power to the drive or
servo on is activated (without giving any command), please inform the distributor for assistance.