User manual

Chapter 4 Display and Operation ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4-6
4-4 General Function Operation
4-4-1 Error Status Display Operation
After entering the parameter mode P4-00 to P4-04, press Set key to display the corresponding error code
history or press UP arrow key to display the error code of H1 to H5 in order. H1 indicates the most recently
occurred error code, H2 is the previous occurred error code before H1 and so forth. Please refer to the
Figure 4.3. The recently occurred error code is 10.
Figure 4.3
SET
or
4-4-2 JOG Operation
After entering parameter mode P4-05, users can follow the following steps to perform JOG operation
(Please also refer to Figure 4.4).
(1) Press the SET key to display the JOG rpm speed. (The default value is 20 rpm).
(2) Press the UP or DOWN arrow keys to increase or decrease the desired JOG speed. (This also can
be undertaken by using the SHIFT key to move the cursor to the desired unit column (the effected
number will flash) then changed using the UP and DOWN arrow keys).
(3) Press the SET when the desired JOG speed is displayed. The Servo Drive will display "JOG"
(4) Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The motor will only rotation
while the arrow key is activated.
(5) To change JOG speed again, press the MODE key. The servo Drive will display "P4 - 05". Press
the SET key and the JOG rpm speed will displayed again. Refer back to #2 and #3 to change
speed.