User manual

Chapter 4 Display and Operation ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4-4
Display Message Description
When the parameter setting is greater than four digits, after the display
value is set, continuously press SHIFT key for many times and then
decimal points in the upper four digits will light. Negative value is
indicated by the lit decimal points in the upper four digits.
If the parameter value is less than five digits, the negative value is
indicated by symbol “Ё”. Reverse rotation is also indicates by symbol
Ё”.
4-3-5 Monitor Setting Display
When the AC servo drive is applied to power, the LCD display will show the monitor display symbols for
approximately one second and then enter into the monitor display mode. In monitor display mode,
pressing UP or DOWN arrow key can change the monitor state or directly change parameter P0-02 to
specify the monitor status. When the power is applied, the setting value of P0-02 is the default monitor
code. For example, if the setting value of P0-02 is 2 when the power is applied, the C.P monitor symbol
will first display and then the pulse command input pulse number will display after.
Settings of P0-02 Display Message Description Unit
0
Feedback pulse number of servo
motor (Absolute value)
[pulse]
1
Feedback rotation number of servo
motor (Absolute value)
[rev]
2
Input pulses of pulse command [pulse]
3
Rotation number of pulse command [rev]
4
Error pulse number of pulse
command and feedback pulse
[pulse]
5
Input frequency of pulse command [kHz]
6
Motor rotation speed [rpm]
7
Speed input command 1 [V]
8
Speed input command 2 [rpm]
9
Torque input command 1 [V]
10
Torque input command 2 [%]