User manual

ASDA-A User Manual Chapter 3 Configuration and Wiring
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED 4th Edition 2005/11/30, HE03
3-21
Signal
DI
Code
Function Pt Pr S T Sz Tz Pt-S Pt-T Pr-S Pr-T S-T
TLLM
25
Reverse operation torque
limit (torque limit function
is valid only when P1-02
is enabled)
TRLM
26
Forward operation torque
limit (torque limit function
is valid only when P1-02
is enabled)
SHOM
27
Move to “Home”
INDEX0
28
Feed step selection
input 0 (bit 0)
INDEX1
29
Feed step selection
input 1 (bit 1)
INDEX2
30
Feed step selection
input 2 (bit 2)
INDEX3
31
Feed step selection
input 3 (bit 3)
INDEX4
32
Feed step selection
input 4 (bit 4)
MD0
33
Feed step mode input 0
MD1
34
Feed step mode input 1
MDP0
35
Manually continuous
operation
MDP1
36
Manually single step
operation
JOGU
37
Forward JOG input
JOGD
38
Reverse JOG input
STEPU
39
Step up input (available
in Pr mode only)
STEPD
40
Step down input
(available in Pr mode
only)
STEPB
41
Step back input.
(available in internal
auto running mode only)
AUTOR
42
Auto run input
GNUM0
43
Electronic gear ratio
(Numerator) selection 0
[see P2-60~P2-62]
GNUM1
44
Electronic gear ratio
(Numerator) selection 1
[see P2-60~P2-62]
INHP
45
Pulse inhibit input