1-6 Molded-case Circuit Breaker, Fuse and Leakage Current
Model Name
OUTPUT
SHORT
CIRCUIT
LEAKING
CURRENT
LEAKING
CURRENT
BREAKER FUSE
Operation Mode General 3-Phase 1-Phase General General
ASD-A0121LA 8.4A (peak) 0.06mA 0.16mA 5A 5A
ASD-A0221LA 8.4A (peak) 0.06mA 0.16mA 5A 5A
ASD-A0421LA 25A (peak) 0.08mA 0.2mA 10A 20A
ASD-A0721LA 42A (peak) 0.08mA 0.2mA 10A 20A
ASD-A1021LA 60A (peak) 0.08mA 0.2mA 15A 25A
ASD-A1021MA 60A (peak) 0.08mA 0.2mA 15A 25A
ASD-A1521LA 66A (peak) 0.09mA 0.21mA 20A 40A
ASD-A1521MA 66A (peak) 0.09mA 0.21mA 20A 40A
ASD-A2023LA 73A (peak) 0.12mA 30A 60A
ASD-A2023MA 73A (peak) 0.12mA 30A 60A
ASD-A3023LA 107A (peak) 0.13mA 30A 80A
ASD-A3023MA 107A (peak) 0.13mA 30A 80A