User manual

Chapter 7 Parameters ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
7-28
2nd Speed Command
P1 - 10 SP2
2nd Speed Limit
Communication Addr.: 010AH
Default: 200 Applicable Control Mode: S
Range: +/-5000
Unit: r/min
2nd Speed Command
In Speed mode, this parameter is used to set speed 2 of internal speed command. For the
decimal place setting of internal speed command, please refer to P2-63.
Default: 200 Applicable Control Mode: T
Range: +/-5000
Unit: r/min
2nd Speed Limit
In Torque mode, this parameter is used to set speed limit 2 of internal speed command.
3rd Speed Command
P1 - 11 SP3
3rd Speed Limit
Communication Addr.: 010BH
Default: 300 Applicable Control Mode: S
Range: +/-5000
Unit: r/min
3rd Speed Command
In Speed mode, this parameter is used to set speed 3 of internal speed command. For the
decimal place setting of internal speed command, please refer to P2-63.
Default: 300 Applicable Control Mode: T
Range: +/-5000
Unit: r/min
3rd Speed Limit
In Torque mode, this parameter is used to set speed limit 3 of internal speed command.
1st Torque Command
P1 - 12 TQ1
1st Torque Limit
Communication Addr.: 010CH
Default: 100 Applicable Control Mode: T
Range: +/-300
Unit: %
1st Torque Command
In Torque mode, this parameter is used to set torque 1 of internal torque command.
Default: 100 Applicable Control Mode: P/S
Range: +/-300
Unit: %
1st Torque Limit
In Position and Speed mode, this parameter is used to set torque limit 1 of internal torque
command.