User manual
Chapter 7 Parameters ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
7-6
Extension Parameters
Control
ModeParameter Name Function Default Unit
P S T
P2-34 SDEV
Overspeed Warning Condition
5000 rpm O
P2-35 PDEV
Excessive Error Warning Condition
30000 pulse O
P2-36
~ P2-43
POV1
~ POV8
Moving Speed Setting of 1st ~ 8th Position 1000 rpm O
P2-44 DOM Digital Output Modes 0 --- O
P2-45 DOD Combination Output Signal Delay Time 1 4msec O
P2-46 FSN Feed Step Number 6 --- O
P2-47 PED Position Deviation Clear Delay Time 0 20msec O
P2-48 BLAS Backlash Compensation of Feed Step Control 0 pulse O
P2-49 SJIT Speed Detection Filter and Jitter Suppression 0 sec O O
P2-50 CCLR Pulse Clear Mode 0 --- O
P2-51 SRON
Servo ON
0
---
OOO
P2-52 ATM0 Timer 0 of Auto Mode 0 sec O
P2-53 ATM1 Timer 1 of Auto Mode 0 sec O
P2-54 ATM2 Timer 2 of Auto Mode 0 sec O
P2-55 ATM3 Timer 3 of Auto Mode 0 sec O
P2-56 ATM4 Timer 4 of Auto Mode 0 sec O
P2-57 ATM5 Timer 5 of Auto Mode 0 sec O
P2-58 ATM6 Timer 6 of Auto Mode 0 sec O
P2-59 ATM7 Timer 7 of Auto Mode 0 sec O
P2-60 GR4 Electronic Gear Ratio (2nd Numerator) (N2) 1 pulse O
P2-61 GR5 Electronic Gear Ratio (3rd Numerator) (N3) 1 pulse O
P2-62 GR6 Electronic Gear Ratio (4th Numerator) (N4) 1 pulse O
P2-63 TSCA Proportion Value Setting 0 times O O
P2-64 TLMOD Torque Limit Dual Mode 0 --- O O