Datasheet

DS_AA04S/D_06172014 E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P2
Output Characteristics
Parameter Conditions Min. Typ. Max. Unit
Output Voltage Accuracy
Single and Dual Output Models
---
±1.0
±2.0
%
AA04D0305A & AA04D0512A
---
±2.0
±5.0
%
Line Regulation
Single and Dual Output Models
---
±0.5
±1.0
%
AA04D0305A &
AA04D0512A
Vo1
---
±0.5
±1.0
%
Vo2
---
±1.0
±3.0
%
Load Regulation
3.3VDC Output Model
---
±1.0
±1.5
%
5~24VDC and Dual Output Models
---
±0.5
±1.0
%
AA04D0305A &
AA04D0512A
Vo1
---
±0.5
±1.0
%
Vo2
---
±2.5
±5.0
%
Ripple & Noise (20MHz)
3.3V & 5VDC Output Models
---
100
150
mV
P-P
Other Output Models
---
0.8
1.0
%V
PP
of Vo
Minimum Load
Single Output and Dual +/- Output Models
No min. Load
required
--- --- %Inom.
Dual +/+ Output Models
---
25
---
%Inom.
Over Voltage Protection
Zener diode clamp
---
120
---
% of Vo
Temperature Coefficient
---
±0.01
±0.02
%/
Overshoot
---
---
5
%Vout
Current Limitation
Foldback, auto-recovery
105 --- --- %Inom.
(long term overload condition may cause
damage)
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
Input to Output, 60 Seconds
3000
---
---
VAC
I/O Isolation Resistance
500 VDC
100
---
---
MΩ
Switching Frequency
---
130
---
KHz
Hold-up Time
---
20
---
ms
MTBF (calculated)
MIL-HDBK-217F@25, Ground Benign
330,000
---
---
Hours
EMC Emission
Conducted and radiated
EN 55011 class B, EN 55022 class B, FCC part 15 class B
EMC Immunity accord
ing
EN61000-6-1
Standard Specification Requirement
Performance
Criteria
EN61000-4-2
Air ±8KV Cont. ±4KV
B
EN61000-4-3
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
EN61000-4-4
AC port ±2KV DC, SL, TL ±2KV not less than 1
min.
B
EN61000-4-5
1.2/50μS(8/20μS) AC dif. ±1KV DC ±0.5KV
B
EN61000-4-6
0.15~80MHz, 10Vrms (functional earth ports
included)
B
80% AM, 1KHz modulation
EN61000-4-8
50Hz/60Hz, 30A/m
A
EN61000-4-11
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
Protection Class II
According IEC/EN 60536
Safety Approvals
cUL/UL 60950-1,IEC/EN 60950-1
Recommended Input Fuse
All Models
External Fuse (Recommended)
1A Slow Blow Type