Operating instructions
9
3~230 V
3~230 V
3~400 V
3~230 V
Caution
Before voltage switching, the drive must be safely disconnected from the mains.
The drives can be operated on a 3~ 400 V (
star connection) or 3~ 230 V ( delta connection) network. The drives are
designed for operation on a 3~ 400 V network.
VoltageswitchingforA80-A280
For operation on a 3~ 230 V network the drive must be switched from star connection to delta connection.
1. Remove the “3 x 230 V” sticker
2. Switch the 6-phase plug from
to .
Voltage switching
3~ 400 V
3~ 230 V
Motor plug
Motor plugAdapter
Control cable plug
Jumper plug
VoltageswitchingforA80AE-A280AE
For operation on a 3~ 230 V network, the adapter with Art. No. 4822 200 203 0 must be used. This is connected between the
motor plug with the coloured wires and the plug with wires 1, 2 and 3 of the control cable.