Operating instructions
15
Technical data
Type Unit
A80/29
A80AE/29
A100/22
A100AE/22
A130/29
A130AE/29
A140/20
A140AE/20
Drive torque T Nm 80 100 130 140
Drive speed n rpm 29 22 29 20
Diameter of hollow shaft mm 25.4 25.4 25.4 25.4*
3)
Operating voltage U V 3~230 / 400 3~230 / 400 3~230 / 400 3~230 / 400
Frequency f Hz 50 50 50 50
Nominal current I A 2.9 / 1.7 3.3 /1.9 4.2 / 2.4 3.8 / 2.2
Performance factor cos j 0.76 0.76 0.78 0.78
Insulation material class H H H H
Thermoswitch °C 170 170 170 170
Mode S3 % 40 40 40 40
Protection type *
1)
IP 54 54 54 54
Limit switch range
Revolutions 24 24 24 24
Static holding torque Nm 400 400 400 400
On-site fuse protection 3x10 AT 3x10 AT 3x10 AT 3x10 AT
Permissible ambient operating temperature
°C -10 to +35 -10 to +35 -10 to +35 -10 to +35
Weight *
2)
(approx.) kg 10 10 11 11
*
1
) Optional IP65 *
2
) with the LK version, the weight is increased by approx. 0.5 kg.
*
3
) Optional 31,75 mm *
4
) without prototype technical-release procedure
Deviations are possible in structually identical drives or special drives.
Theinformationonthetypeplatealwaysapplies.
Subject to technical changes without notice
Type Unit
A150/13
A150AE/13
A220/13
A220AE/13
A280/12*
4)
A280AE/12*
4)
Drive torque T Nm 150 220 280
Drive speed n rpm 13 13 12
Diameter of hollow shaft mm 30 30 30
Operating voltage U V 3~230 / 400 3~230 / 400 3~230 / 400
Frequency f Hz 50 50 50
Nominal current I A 3.3 /1.9 4.2 / 2.4 5.0 / 2.9
Performance factor cos j cos j 0.76 0.78 0.78
Insulation material class H H H
Thermoswitch °C 170 170 17 0
Mode S3 % 25 25 25
Protection type *
1)
IP IP 54 54 54
Limit switch range
Revolutions 24 24 24
Static holding torque Nm 400 400 400
On-site fuse protection 3x10 AT 3x10 AT 3x10 AT
Permissible ambient operating temperature
°C -10 to +35 -10 to +35 -10 to +35
Weight *
2)
(approx.) kg 10 11 11