S1F -Safety limit switchOPEN-yellow
S2F -Safety limit switchCLOSE-yellow
S3F -Safety limit switch HK/LK
S4F -Thermoswitch
Attention
The individual wires must not be in contact with the cams of the limit switch when the housing cover is
closed.
S5 -Operational limit switch OPEN-grey
S6 -Operational limit switchCLOSE-black
S7 -Functional limit switch-orange
S7 -Functional limit switch-green
Electric connection to the control unit and connection diagram
Caution
The electric connection may only be carried out by a qualified electrician! Please observe the informa-
tion on the control unit to be used and the applicable EN standards! When all connection work is being
carried out, the door system must be safely disconnected from the mains by removing the plug/switching
off the main switch. Observe the drive's technical data. The limits given in the technical data must not be
exceeded.Inparticular,protectionofthedoorsystemwhichistobeperformedbythecustomermustbe
carried out in accordance with the technical data!
When laying the protective conductor, it must be ensured that the protective conductor connection is
disconnected last if the cable is pulled out unintentionally, e.g., by bundling the individual black wires of
theconnectingcabletogethertoformaloopandxingthiswithacabletie.
Then lay the connecting cable in such a way that it is not in contact with the drive.
ElectricconnectiontothecontrolunitandconnectiondiagramforA80-A280
To connect the drive to the control unit, only use original 12-core or 18-core control cables which have been approved by
the manufacturer. The control cable can be plugged in. In order to guarantee strain relief and the protection type, the screw
connection must not be undone. To plug in the 18-core control cable the 10 pole jumper plug in the drive must be removed.
The plugs feature reverse polarity protection and click audibly into place. The yellow/green protective conductor wire must be
connected to the designated push-on connector . Make sure that it engages rmly.