Installation guide RADIO TYBOX PAC Wireless programmable thermostat for heat pumps RADIO TYBOX Device compliant with the requirements of directives: R&TTE 1999/5/CE *2701907_rev1* DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed by Delta Dore.
Warnings Contents Carefully read these instructions prior to installation. • The unit must be installed in compliance with currently applicable standards. • Always switch off the mains before installing or servicing the unit. • Do not attempt to repair the unit yourself; an aftersales service is available. • Check that the fastenings are suited to the surface that the unit will be attached to (plasterboard, brick, etc.). • The diagrams provided are simplified for greater clarity.
Contents Presentation Advanced configurations (menu 2) . . . . . . . . . 19 Modification authorization for the user . . . . . . . . . Correction of the measured temperature . . . . . . . Automatic mode temperature display option . . . . . Regulation time base . . . . . . . . . . . . . . . . . . . . . . Selection of the opening direction of the change-over relay . . . . . . . . . . . . . . . . . . . . . . . . . 19 20 20 20 20 Radio association (menu R) . . . . . . . . . . . . . .
Location of the receiver The receiver must be positioned near the heat pump control unit (e.g. Hydraulic module). Mounting the receiver Removing the cover 2 To remove the cover, push the tab and lift the cover. To avoid interference with the radio transmission, the antenna must be free from any metallic elements (cables, metallic covers, etc.).
Connecting the receiver Location / Mounting the transmitter For easier use, the RADIO TYBOX can be installed: - on a wall: at an approximate height of 1.5 m, with screws/plugs, Connect the control wires, pass the wires through the provided raceway or through the pierced hole 1 . - on a support: Placed on an item of furniture or a shelf. Refer to the section that deals with your type of installation. 1 When the connection is made, fit the cover and switch on the current at the circuit breaker.
Fitting to the base Non-reversible heat pump Position the unit on its base and lock it. 1 Position the thermostat on its base. Do not wire the output S1 2 Lock the thermostat Mode 1 RF 652 230 V Com S1 S2 1 2 3 4 5 Thermostat input Power supply 230 V - Menu configuration Modifying the positions of the receiver’s outputs 1-06 Choice of the heat pump type 1 = Non-reversible heat pump (heat only) If necessary, the On position for the thermostat output can be switched around.
Reversible heat pump thermostat + change-over Mode 1 RF 652 230 V Com S1 S2 Thermostat input 1 2 3 4 5 Power supply 230 V Heat pump relay common contacts Change-over input Reversible heat pump with 2 thermostat inputs (cool / heat) Mode 2 For this type of use, the receiver must be set to mode 2 before wiring the heat pump’s heat and cool inputs on the thermostat.
On the RADIO TYBOX: - Pres the button i, the receiver is set to mode 2 - Turn the knob to AUTO to exit the association mode - Cut off the power supply to the receiver and connect it to the heat pump. Starting up When you turn the unit on for the first time, you will need to set the time. Minutes Days RF 652 The S1 output controls the thermostat’s cool input. The S2 output controls the thermostat’s heat input.
Configuration Basic configurations (menu 1) To access the configuration menus, Press button 1, - turn the knob to , - press the i button to display the temperature - then press the i button for 5 seconds. 5 sec. To change the various settings, press the + or - buttons, then press OK to confirm the change and go to the next setting. The unit will propose 4 configurations to choose from: Weekly (by default) Unit version (e.g.
For hot water heaters with thermostatic valves, the Comfort temperature can be provided by adjusting the thermostat of each radiator. In this case, only Economy and Frost Protection temperatures are set by the RADIO TYBOX. Advanced configurations (menu 2) Comfort temperature set by the TYBOX (by default) Controlling the Comfort temperature Comfort temperature controlled by each radiator or fan coil unit. Here, the display reads ConF during Comfort period. Press button 2.
Correction of the measured temperature Correction possible from -5°C to +5°C in increments of 0.1°C. Press the + or - buttons to make changes, and confirm with the OK button. E.g. If the temperature displayed by the unit is 19°C and the temperature measured is 20°C, add 1°C to the display and confirm by pressing OK. Automatic mode temperature display option Continuous set-point temperature display (by default). With this option, press i to display the room temperature.
Press + or - to make your choice. Press OK to confirm and go to the next mode. “Consumption indication” feature Radio association (menu R) Associating radio products with the RADIO TYBOX From the menu rAd. To associate a consumption indicator with the RADIO TYBOX (e.g. RADIO TYWATT). No consumption indication Consumption indication function Consumption indicator to associate Press + or - to display 1 flashing. Confirm on the RADIO TYWATT. Check on the RADIO TYBOX that flashing.
2nd step: Associating the home automation products. On the home automation product to associate, confirm the association as indicated in the table or refer to its user guide. Each newly associated product is displayed on the screen. Number of associated transmitters Product Product 1 2 3 4 5 6 7 8 9 0 # Remote control of the installation TYXAL control unit Association Press the button.
Configuration des options (menu 3) Product Home automation remote control The menus 3-12 to 3-18 are only accessible if the RADIO TYBOX is associated with a RADIO TYWATT. Association Press the domain button until until the remote control emits a beep and the symbol flashes.
Configurations 3-13 to 3-18 let you modify costs according to your subscription. Subscription option Removing radio associations Base Double tariff tempo EJP Base OP OP blue day Normal hours - PH PH blue day Peak hours - - white day OP - - - white day PH - - - red day OP - - - red day PH - To cancel all radio associations, turn the knob to , then hold the i button down for 5 seconds. (this action also removes the displayed consumption information).
Return to the factory configuration A return to the factory configuration is possible for menus 1, 2, and 3. Turn the knob to , then press and hold the i button for 5 seconds. Radio test Turn the knob to , then hold the 2nd button (from the top) down for 5 seconds until tESt appears. 5 sec. Press the button of the menu you wish to reset, and hold the button for 5 seconds (this example uses menu 1). The HEAT LED on the receiver should flash for each reception (approximately every 6 seconds).
1-06 1-08 1-09 2-01 Choice of heat pump type 0 = reversible heat pump (by default) 1 = Non-reversible heat pump (heat only) Controlling the Comfort temperature 0 = set by the RADIO TYBOX (by default) 1 = by each radiator or fan coil unit.
Technical characteristics Technical characteristics RADIO TYBOX transmitter RF 652 receiver • Power supplied by two LR03 or AAA-type 1.
Troubleshooting Nothing is displayed on the room unit screen. There is no power supply Check the batteries. The receiver does not accept orders from the transmitter. • Check the transmission by performing a radio test. • Move your transmitter if necessary. • Repeat the radio-controlled association of the receiver with the RADIO TYBOX. The indication is displayed. The batteries are low. Change the batteries, making sure they are the right way round. The unit displays: dEF 6.