Installation Guide
CARE AND MAINTENANCE
TURN OFF POWER SOURCE. REVIEW ALL
SAFETY PRECAUTION.
See safety information before proceeding. Routine
maintenance should be done at least once a year.
Never use solvents, thinner or harsh chemicals when
cleaning the fan.
Do not allow water to enter the motor.
Do not immerse metal parts in water.
Do not immerse resin parts in water over 140º F.
1.
To remove grille, squeeze springs and pull down.
Wash and clean grille with non-abrasive kitchen
detergent. Then wipe dry with a new cloth.
2.
Remove dust and dirt from the fan body with a
vacuum cleaner.
3.
Using a cloth dampened with non-abrasive kitchen
detergent, remove dust and dirt from the fan body.
Then wipe dry with new cloth.
4.
Replace the grille back onto the fan body. Turn on fan
switch to operate fan again.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (‘‘Delta Electronics’’) warrants to the
original consumer purchaser in the USA and Canada that
the Breez ventilation fan products will be free from
defects in material or workmanship. This warranty is
limited to three (3) years from the original date of
purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must include
the product model number, and must be made
through an authorized Delta Electronics distributor.
Authorized returns must be shipped prepaid. Repaired
or replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action whether
in contract, tort (including negligence), strict product
liability or otherwise.
4. The warranty does not cover if user does not comply
with manufacturer’s installation manual.
5. To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
6. Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by
abuse, misuse, neglect, improper transportation or
storage, improper testing, improper installation,
improper operation, improper use, improper
maintenance, improper repair, improper alteration,
improper modification, tampering or accident of
products or parts thereof, or unusual deterioration or
degradation of products or parts thereof due to a
physical environment beyond the requirements of
products’ specifications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number:
1-888-979-9889 - Technical Support
1-877-685-4384 - Customer Sales Support
www.deltabreez.com
TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
T
he fan is not turning on 1. Power off
2. Faulty switch
3. Faulty wire connection
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
T
he fan seems louder than it
should
1. CFM too great
2. Damper not working properly or
damaged
3. Bend in duct too close to fan
discharge
4. Fan discharge reduced to fit
smaller duct
5. Fan body not securely attached
1. Be sure the CFM rating on the fan matches the
size of your room.
2. Check damper to ensure it is opening and
closing properly. If the damper has become
damaged, please call Customer Service.
3. Be sure you do not have any sharp bends in
duct closer than 18 in. to the fan discharge.
4. Use recommended size ducting to reduce fan
noise.
5. Be sure the fan is securely attached to your
ceiling joists.
T
he fan is not clearing the
room
1. Insufficient intake airflow within
room
2. Insufficient CFM
1. Be sure a door or window is slightly ajar or
opened to allow airflow. The fan is not able to
draw air out of the room without enough
airflow to draw in from.
2. Be sure the CFM rating on the fan matches the
requirements for your room size.
T
he fan keeps running even
though the house humidity
level is lower than user-
adjustable set-point.
1. Our sensor tolerance is +/- 10%
RH
2. Outdoor humidity is back
drafting to the fan
1. Continue to let the fan run since it is good to
keep venting the house and the electric bill is
minimal (approximately less than $10 per
year).
2. Turn the fan off when not in use.
T
he light is not turning ON 1. Power off
2. Faulty switch
3. Faulty wire connection
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
DIMENSIONS
ELT80-110, ELT80-110D,
ELT80-110H, ELT80-110MH
ELT80-110LED, ELT80-110DLED,
ELT80-110HLED, ELT80-110MHLED
SPECIFICATIONS
Model No.
Voltage
(V)
Frequency
(Hz)
Air Flow
@ 0.1SP
(CFM)
Power
@ 0.1SP
(W)
Max
Current
(amps)
Weight
(lb.)
Note Light Spec
ELT80-110 120 60 110 10.3 0.27 6.5
Single
Speed
-
ELT80-110D 120 60 110 10.3 0.27 6.6
Dual
Speed
-
ELT80-110H 120 60 110 10.3 0.27 6.6
Humidity
Sensing
-
ELT80-110MH 120 60 110 10.3 0.27 6.6
Humidity
& Motion
Sensing
-
ELT80-110LED 120 60 110 10.3 0.28 7.1
Single
speed
13 Watts,
850 Lumens,
3000K, CRI90
ELT80-110DLED 120 60 110 10.3 0.28 7.2
Dual
Speed
13 Watts,
850 Lumens,
3000K, CRI90
ELT80-110HLED 120 60 110 10.3 0.28 7.2
Humidity
Sensing
13 Watts,
850 Lumens,
3000K, CRI90
ELT80-110MHLED 120 60 110 10.3 0.28 7.2
Humidity
& Motion
Sensing
13 Watts,
850 Lumens,
3000K, CRI90
Note: Specifications subject to change without notice.
1.
4.
2.
3.
Page 4.