Operation Manual

13
Rinsing the steam generator - Disposal
Rinsing the steam generator
After every 10 ironing sessions, proceed as descri-
bed on page 7.
Disposal
In compliance with European directive 2002/96/EC,
the appliance must not be disposed of with household
waste, but taken to an authorised waste separation and
recycling centre.
PROBLEM CAUSE REMEDY
The appliance does not come on. The appliance is not plugged into a
mains socket.
Make sure the appliance is correctly
connected and press the iron and steam
generator buttons.
Steam comes from behind the tank. The maximum pressure safety system
has tripped.
Turntheapplianceoimmediately
andcontactanauthorisedDe'Longhi
Customer Services.
Water leaks out from the holes in the
bottom of the sole plate.
Water has condensed inside the tubes
because steam is being used for the rst
time, or has not been used for some time.
Press the steam button several times away
from the ironing board. This will eliminate
cold water from the steam circuit.
The ironing system is positioned on an
unstable and/or sloping surface.
Rest the ironing system on a stable at
surface.
Browncoloureduidleaksfromthe
sole plate.
Chemical water softeners or additives
have been poured into the water tank or
steam generator.
Never pour products into the water tank
(see “What water to use”). Clean the sole
plate with a damp cloth.
The rst time the appliance is turned on,
you notice smoke
Some parts have been treated with
sealer/lubricant which evaporates the
rst time the iron heats up.
This is normal and will stop when you
have used the iron a few times.
The appliance emits an intermittent
noise associated with vibrations.
Water is being pumped into the steam
generator.
This is completely normal
The appliance emits a continuous noise
associated with vibrations.
Unplug the system from the mains
andcontactanauthorisedDe'Longhi
Customer Services.
After topping up with water, the light
does not reset.
The steam lock is on. Release the steam lock O and press the
OK button.
The lter has been removed for
maintenance/replacement.
Repeat the ll procedure used when the
iron was turned on for the rst time.
After regenerating/replacing the lter,
the light does not reset.
Press and hold the OK button down for
a few seconds.
Troubleshooting
en
en