Safety data sheet
De’Longhi Group
Revision No. 1
Dated 19/02/2016
Printed on 19/02/2016
Pagina n. 5/11
Ser3013 - MILK CLEAN
ETHANOLAMINE
Threshold Limit Value.
Type
Country
TWA/8h
STEL/15min
mg/m3
ppm
mg/m3
ppm
MAK
AUS
2,5
1
7,6
3
SKIN.
VLEP
BEL
2,5
1
7,6
3
SKIN.
VEL
CHE
5
2
10
4
MAK
CHE
5
2
10
4
AGW
DEU
5,1
2
10,2
4
SKIN.
MAK
DEU
5,1
2
10,2
4
VLEP
FRA
2,5
1
7,6
3
SKIN.
WEL
GRB
2,5
1
7,6
3
SKIN.
OEL
IRL
2,5
1
7,6
3
SKIN.
TLV
ITA
2,5
1
7,6
3
SKIN.
OEL
EU
2,5
1
7,6
3
SKIN.
TLV-ACGIH
7,5
3
15
6
Legend:
(C) = CEILING ; INHAL = Inhalable Fraction ; RESP = Respirable Fraction ; THORA = Thoracic Fraction.
8.2. Exposure controls.
As the use of adequate technical equipment must always take priority over personal protective equipment, make sure that the workplace is well aired
through effective local aspiration. Personal protective equipment must be CE marked, showing that it complies with applicable standards.
Provide an emergency shower with face and eye wash station.
HAND PROTECTION
Protect hands with category III work gloves (see standard EN 374).
The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability.
The work gloves' resistance to chemical agents should be checked before use, as it can be unpredictable. The gloves' wear time depends on the duration
and type of use.
SKIN PROTECTION
Wear category I professional long-sleeved overalls and safety footwear (see Directive 89/686/EEC and standard EN ISO 20344). Wash body with soap
and water after removing protective clothing.
EYE PROTECTION
Wear airtight protective goggles (see standard EN 166).
RESPIRATORY PROTECTION
If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, use a mask with a type B filter
whose class (1, 2 or 3) must be chosen according to the limit of use concentration. (see standard EN 14387). In the presence of gases or vapours of
various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required.
Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold
values considered. The protection provided by masks is in any case limited.
If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear
open-circuit compressed air breathing apparatus (in compliance with standard EN 137) or external air-intake breathing apparatus (in compliance with
standard EN 138). For a correct choice of respiratory protection device, see standard EN 529.
ENVIRONMENTAL EXPOSURE CONTROLS.
The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with
environmental standards.