Instruction Manual

11
en
Troubleshooting
NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE
TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side, oil needs to return to the
compressortoensureproperfunction.Withoutallowingtheunitthistime(6-24hours)Theunitmayfunctionforonlyashorttime,
and then the compressor will break down from lack of oil.)
PROBLEM CAUSE REMEDY
The air
conditioning unit does not start.
• Noelectricity.
• Itisnotpluggedintotheoutlet.
• Thesafetydeviceoftheplughas
tripped.
• Wait.
• Plugintotheoutlet.
• Resetthesafetydevice,ifproblem
persists contact our toll free
customer service.
The air
conditioning unit works for a short
time only.
• Theairexhausthosehasaconstric-
tion.
• Theairexhausthoseisblocked.
• Therearetightbendsintheair
exhaust hose.
• Positiontheexhausthosecorrectly.
• Checktherearenoobstacles.
Obstructing air discharge.
• Eliminatethetightbends.
The air
conditioner works, but does not
cool the room.
• Windowopen.
• Theexhausthoseisdetached.
• Airltersclogged.
• closethewindow.
• connecttheexhausthose.
• cleanorreplacethelter.
Particular odour in the room • airpurifyingltersclogged • cleanorreplacethelters.
The air conditioner does not
operate for about 3 minutes after
turning it on
• thesafetydevicehastripped • waitforthreeminutes.
The alarm light Q comes on • thetankinsidetheapplianceisfull. • emptythetank(see“Endofseason
operations) on page 10).
IF…IS DISPLAYED, IF…IS DISPLAYED, IF…IS DISPLAYED,
“Low Temperature”
...MEANS: room temperature is too low
“High Temperature
...MEANS: room temperature is too high
“Probe Failure”
(sensor damaged)
MEANS: contact your local customer service
SELF-DIAGNOSIS
The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance
display.