• Refrigerantgasmaybeodourless.
• The appliance must be installed, used and
storedinaroomwithasurfaceareagreater
than15m².
• Thisappliancecontainsabout300gofR290
refrigerantgas.
• R290refrigerantgascomplieswithEuropean
environmentaldirectives.
Donot perforate any of thecomponents in
therefrigerantcircuit.
• Ifthe applianceisinstalled, used orstored
inanunventilatedroom,theroommustbe
such as to prevent stagnation of possible
leaksofrefrigerantgasastherecouldbea
dangerofreorexplosionhazardshouldthe
refrigerant come into contact with electric
heaters,stovesorothersourcesofignition.
• Theappliancemustbestoredinsuchaway
astopreventmechanicalfaults.
• Personsworkingonarefrigerantcircuitmust
havetherelativeauthorisationissuedbyan
accreditedbodycertifyingtheircompetence
tohandle refrigerants incompliancewith a
standard assessment recognised by sector
associations.
• Allrepairsmustbecarriedoutinaccordance
withthemanufacturer’srecommendations.
Maintenance and repairs requiring the
assistance of other qualied personnel
must be carried out under the supervision
of specialists in the use of inammable
refrigerants.
Disposing of the appliance
IncompliancewithEuropeandirective
2002/96/EC,theappliancemustnotbe
disposedofwithhouseholdwaste,but
takentoanauthorisedwasteseparation
andrecyclingcentre.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains
socket,checkthat:
• themainspowersupplycorrespondstothe
value indicated on the rating plate on the
backoftheappliance;
• the power socket and electrical circuit are
adequatefortheappliance.
• themainssocketmatchestheplug.Ifthisis
notthecase,havetheplugreplaced;
• themainssocketisadequatelyearthed.
Failure to follow these important safety
instructionsabsolvesthemanufacturerofall
liability.
WHAT IS THE INVERTER PINGUINO
The Inverter technology has been designed to
of¬fer the best comfort with optimised energy
consumption. It guarantees very high cooling
power to rapidly reach the set temperature,
whichisthenmaintainedconstantovertime.
Thistechnologyisessentiallybasedonanelec-
tronicdevicethatallowsfrequencyvariationsof
theelectricmotor,toadjusttherotationspeedof
thecompressorandobtainamodulationofthe
coolingpower.
ThisdeviceeliminatesthesequenceofOn–Off
requiredbyconventionalairconditionerstokeep
a xed room temperature, with consequential
high temperature uctuations around the set
temperature and longer time gaps before it is
reached.
ThePinguinoInverteralwaysoperatesattheop-
timumcoolingcapacityandthemaximumenergy
efciencyasthepowerconsumptionislimitedto
effectiverequirements,bothinperiodsofavera-
geandlow thermal load(morningorevening),
and during the hotter and more hu¬mid times
(middleoftheday),whentheInvertertechnolo-
gyisespeciallyvaluable.