LIGHTS ALARM SOLUTION
+ ashing
If the water softener lter (C6) is present,
an air bubble may have been released in-
side the circuit, obstructing delivery
Remove water softner lter and press the but-
ton (B6) corresponding to the light (g.
9). Delivery begins and stops automatically.
Reinsert water softner as described in section
"11. Activating the water softener lter"
The grinding is too ne and the coee is
delivered too slowly or not at all
Extract the portalter using caution. Remove
any cup or glass from the tray. Hold rmly the
portalter and remove it slowly. Then repeat
the operations to make the coee, bearing in
mind the indications in section "4.2 Select
the coee grinding (coarse to ne)" and the
"16. How to make perfect coee" table.
Excessive coee dosage in the lter
caused overpressure and the coee is
delivered too slowly or not at all
The lter is blocked, or the perforated
lter is missing
Clean as described in section "13.4 Coee
lter cleaning and maintenance" and make
sure the perforated lter is put back correctly
The tank has been inserted incorrectly
and the valves on the bottom are not
open
Press the tank down lightly to open the
valves on the bottom
Scale in the water circuit Descale as described in section "14.
Descaling"
+ ash briey at regular
intervals
The dial (B2) has been turned to the max-
imum adjustment possible
When not enough coee is ground to
reach the perfect coee dose, contact
De'Longhi Customer Service who will
guide you to reach the perfect dose again
(see "www.delonghi.com")
19. TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
No espresso coee is delivered No water in the tank (A17) Fill the tank
The
light is on and the
light is ashing to indicate that the cof-
fee or steam circuit is empty.
Press the button corresponding to the
light to ll the circuit.
The lter is blocked, or the perforated
lter is missing
Clean as described in section "13.4 Coee
lter cleaning and maintenance" and make
sure the perforated lter is put back correctly
The tank has been inserted incorrectly
and the valves on the bottom are not
open
Press the tank down lightly to open the
valves on the bottom
Scale in the water circuit Descale as described in section "14.